10.1” mini bedside terminal
samsung s5pv210 800mhzprocessor
ultra low power consumption
fanless & compact design (35 pages)
Summary of Contents for Onyx BE185
Page 1
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 BE185 18.5” Bedside Terminal ® Intel ULV U7500 Processor High Performance Low Power Consumption Wide LCD with Multimedia BE185 Manual 2nd Edition July. 2012...
Page 2
ONYX Healthcare Inc., assumes no liabilities resulting from errors or omissions in this document, or from the use of the information contained herein ONYX Healthcare Inc. reserves the right to make changes in the product design without notice to its users...
Page 3
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 Acknowledgments ® Intel Core™ 2 Duo U7500 is a registered trademarks of Intel ® Corporation.
Page 4
BE185 Bedside Terminal. VESA Mount Screws Utility CD-ROM (Please insert the ONYX-BE185 CD-ROM into external CD-ROM drive.) which contains User’s Manual (in PDF format), Drivers and Utilities If any of these items are missing or damaged, you should contact your distributor or sales representative immediately.
Page 5
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 Worldwide Offices: Onyx Healthcare, USA Inc. 2663 Saturn St. Brea, CA 92821, USA Tel : +1-714-996-1800 Fax: +1-714-996-1811 Email: usasales@onyx-healthcare.com...
Page 6
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 Onyx Healthcare (SU ZHOU) INC. Room 12, 2F, Building B, No.5 Xing Han Street, Suzhou Industrial...
Page 7
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 Safety & Warranty Read these safety instructions carefully. Keep this user's manual for later reference. Disconnect this equipment from any AC outlet before cleaning.
Page 8
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 If any of the following situations arise, get the equipment checked by service personnel: a. The power cord or plug is damaged. b.
Page 9
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 Caution: It may cause the danger of explosion if battery is incorrectly replaced. Replace only with same or equivalent type recommended by the manufacturer.
Page 10
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 Classification Degree of production against electric shock: not classified Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide.
Page 11
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 This device complies with Part 15 FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received including interference that may...
Page 12
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 UL Module Description BE185 AC modules are developed to suitable for the Classification Mark requirement...
Page 13
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 Safety Symbol Description The following safety symbols are the further explanations for your reference. Medical equipment with respect to electric shock, fire and mechanical hazards only in accordance with UL 60601-1, and CAN/CSA C22.2 NO.
1.3 Specification ..............1-4 1.4 Dimension ..............1-10 Chapter 2 Hardware Installation 2.1 Safety Precautions ............2-2 2.2 A Quick Tour of the BE185 ..........2-3 2.3 Mounting Installing ............2-6 Chapter 3 Award BIOS Setup 3.1 System Test and Initialization........3-2 3.2 Award BIOS Setup.
Page 15
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 3.13 Set Supervisor/User Password ........3-7 3.14 Save & Exit Setup ............3-8 3.15 Exit without saving ............3-8 Chapter 4 Driver Installation 4.1 Installation ..............
1.1 Introduction —A bedside terminal solution for ultimate patient services that boosts patient satisfaction and well-beings. BE185 offers a highly scalable bedside infotainment solution to enhance patient experiences within the hospital. Packaged with renowned software solution partners, ONYX-BE185 bedside terminals provide patients with capabilities like Entertainment on Demand, Online Access, VoIP Phone, Nurse Notification, etc.
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 TV/Radio Broadcasting 1.2 Feature 18.5” Wide Color TFT LCD display Intel® Core™ 2 Duo U7500 Processor ...
Intel® Core™ 2 Duo U7500 1.06GHz Processor LCD Controller Intel®945GME, Shared memory up to 224MB System Memory Up to 2GB DDRII 533/667 with WLED BE185: 18.5” Wide Color TFT LCD Display Backlight Windows® 7 (32 bit & 64 bit ) Windows® XP Pro OS Support Windows®...
Page 20
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 1 x Smart Card Reader 1 x 2nd Smart Card Reader/RFID Module (Optional) Volume + Volume –...
Page 21
1 x RJ-11 connector for VoIP/Analog phone IP TV, HD TV, Digital TV Support Content Web Gaming/Radio Video Streaming (MPEG2, 3, 4) LCD Specification Model BE185 Series with WLED Backlight Display Type 18.5” Color TFT LCD Chapter 1 General Information...
Page 22
This is a normal occurrence for all LCD displays from all manufacturers and should not be noticeable or objectionable under normal operation. ONYX LCD panels are qualified for industry standard conditions in the following: total 7 dead pixels on a screen or if there are 3 within 1 inch square area of each other on the display.
Page 23
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 Color White/Gray Mounting / Holder VESA 75/100mm, Desk Top, Wall Mount, Ceiling Mount Construction 3mm ABS + PC Plastic Housing Dimension (WxHxD) 510 x 385 x 60.9 (mm) Carton Dimension...
Page 24
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 HDD Bay Internal Power Supply Requirement Power Supply FSP Group Inc. Adapter Mode: 90 W Model No.
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 2.1 Safety Precautions Always completely disconnect the power cord from your board whenever you are working on it.
O N Y X - B E 1 8 5 2.2 A Quick Tour of the BE185 Before you start to set up the BE185, please take a moment to familiarize yourself with the locations and purposes of the controls, drives, connections and ports.
Page 30
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 Picture 2.2: Bedside Terminal Bottom-Up View Picture 2.3: Front Panel Closer Up View LCD On/Off Brightness: + Volume: -- Barcode...
Page 31
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 On the back of BE185 Bedside Terminal, the back I/O section (Digital IO, USB, LAN, and Power connector) is just below the VESA mounting area.
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 2.3 Mounting Installing Onyx-BE185 is suitable for VESA75/100mm interface pads for desktop stand. Attention: When operating the Medical PC, please allow 15cm clearance area for optimal heat dissipation.
The CMOS memory has lost power and the configuration information has been erased. The ONYX-BE185 SD CMOS memory has an integral lithium battery backup for data retention. However, you will need to replace the complete unit when it finally runs down.
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 3.2 Award BIOS Setup Awards BIOS ROM has a built-in Setup program that allows users to modify the basic system configuration. This type of information is stored in battery-backed CMOS RAM so that it retains the Setup information when the power is turned off.
Page 36
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 PnP/PCI Configurations This entry appears if your system supports PnP/PCI. PC Health Status This menu shows you the status of PC. Frequency/Voltage Control This menu shows you the display of frequency/Voltage Control.
ONYX-BE185. 3.6 Integrated Peripherals Choosing the Integrated Peripherals from the INITIAL SETUP SCREEN menu, and you will see the screen contains the manufacturer’s default values for the ONYX-BE185. Chapter 3 Award BIOS Setup...
3.7 Power management Setup Choosing the Power Management Setup from the INITIAL SETUP SCREEN menu, and the screen contains the manufacturer’s default values for the ONYX-BE185. 3.8 PnP/PCI configuration Choosing the PnP/PCI configurations from the Initial Setup Screen menu, and you will see the screen contains the manufacturer’s default values for the ONYX-BE185.
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 3.12 Load Optimized Defaults When you press <Enter> on this item you get a confirmation dialog box with a message similar to: Load Optimized Defaults (Y/N)? Pressing "Y"...
Setup program without recording any new value or changing old one. For more detailed information, you can refer to the "ONYX BIOS Item Description.pdf" file in the CD for the meaning of each setting in this chapter. Chapter 3 Award BIOS Setup...
M e d i c a l S t a t i o n O N Y X - B E 1 8 5 Chapter Driver Installation Chapter 4 Driver Installation 4-1...
Page 42
M e d i c a l S t a t i o n O N Y X - B E 1 8 5 There are several installation ways depending on the driver package under different Operating System application. Please insert the BE-185 Utility CD-ROM into the UL approved external CD-ROM drive.
Page 43
M e d i c a l S t a t i o n O N Y X - B E 1 8 5 4.1 Installation Insert the ONYX-BE185 CD-ROM into the CD-ROM drive and install the drivers from Step 1 to Step 8 in order. (Other drivers will be optional).
Page 44
M e d i c a l S t a t i o n O N Y X - B E 1 8 5 3. The system will help you install the driver automatically Step 4 – Install Audio Driver 1.
Page 45
M e d i c a l S t a t i o n O N Y X - B E 1 8 5 Step 7 – Install TV Card (Optional) 1. Click on the Step 7 –TV Card driver folder and select the corresponding folder for your operating system and double click on Setup.exe file 2.
ONYX Healthcare Inc. has tested and verified these cleaning disinfectants, CIDEX, Viraguard, Control III Disinfectant Germicide, Caviwipes, Dispatch Disinfectant Cleaner CLH69101, Puregreen 24 Disinfectant, as safe to be used with the BE185. Use of any other disinfectants will void the warranty. Appendix B Miscellaneous B...
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 B.2 Cleaning Tools Although many companies have created products to help improve the process of cleaning your computer and peripherals users can also use household items for cleaning purposes.
Page 53
B e d s i d e T e r m i n a l O N Y X - B E 1 8 5 • Cotton swabs - Cotton swabs moistened with rubbing alcohol or water are excellent tools for wiping hard to reach areas in your keyboard, mouse, and other locations.
For computers that are no longer useful, please contact worldwide distributors for recycling. The worldwide distributors are shown on the following website: http://www.onyx-healthcare.com.tw/Contact.php Note: Please follow the national requirement for unit disposal. Appendix B Miscellaneous B...
Need help?
Do you have a question about the BE185 and is the answer not in the manual?
Questions and answers