7.3.3 Test Points
7.3.3
Test Points
Line Output Level - 1 + Gnd
Receive Signal Strength - 1 + Gnd
Tuning Voltage - 1 + Gnd
Serial Data (RS232) - 2 + Gnd
7.4
Electrical Specifications
7.4.1
Power Requirements
Operating Voltage - 10.5 to 16 Vdc
Current Drain - 250mA Max.
Polarity - Negative Ground
7.4.2 Frequency Range and Channel Spacing
215 – 240 MHz 12.5KHz
7.4.3
Frequency Synthesizer Step Size
5.0 or 6.25 KHz
7.4.4
Frequency Stability
+/- 1 ppm, 0 to +60 C
7.4.5
Nominal Antenna Impedance
50 Ω
Page 20