For your future reference please keep this manual in a safe place. Thank you for specifying a product from the Francis Searchlights range. All Francis products are designed to give complete customer satisfaction and are manufactured to the highest engineering standards in order to ensure optimum performance and service life.
2 - Safety Precautions The following instructions must be adhered to, in order to ensure a safe working environment and the safety of the user. Note: When unpacking or manoeuvring the searchlight into its fixing position, suitable lifting points must be used in order to prevent damage to the equipment or personal injury.
3 - Technical Information This product has been designed to operate in accordance with the product specification. The L560 searchlight has the following features: All marine grade materials and fixings; Parabolic formed aluminium reflector; Powder coated; External lamp focus adjustment;...
4 - Unpacking and Installation Instructions The following instructions should be read and fully understood prior to installing the equipment to ensure that the correct procedures are followed, and all safety precautions are observed. Note: If the equipment has been in storage for a considerable amount of time, it is advisable to conduct a routine maintenance check on all parts before installation.
5 - Electrical Installation For safety purposes, only competent personnel should perform the electrical installation. All equipment should be installed to current Electrical Regulations and Standards. In order to obtain the maximum light output from the searchlight, it is essential that the full operating voltage of the lamp fitted be applied to the lampholder contacts.
6 - Operating Instructions This equipment is designed for use out of doors, in free air. Never place anything on or cover the searchlight when in use as this may present a hazard. The searchlight can be positioned using the elevation and base lockwheels. When in the desired position the lockwheels must be securely fastened to prevent damage.
Page 9
When fitting the lamp: Always isolate the equipment from the supply when inserting a lamp; Ensure the circuit is suitably fused; Ensure the lamp is of the correct power rating and type; Check lampholder is in good condition. If the contacts show any sign of corrosion, replace the lampholder;...
7 - Fault Finding All fault finding must be conducted by a competent person or qualified Electrical Engineer. Failure of Lamp to light Causes: 1) Power not supplied; 2) Fuse blown; 3) Failed lamp Remedy: 1) Check voltage at supply. If supply is not present the fault is at the customer supply. If power is present, see remedy 2;...
8 - Maintenance and Servicing In order to prolong the service life and performance of your searchlight, the following maintenance guidelines are recommended: Maintenance checks should be conducted before very voyage or at least every three months; Before checking, disconnect the equipment from the supply; ...
9 - General Assembly Drawing Number Description A2969 General Assembly drawing L560D A2993 General Assembly drawing L560C A2893 General Assembly drawing L560DP A2882 General Assembly drawing L560CP...
Bellows In order to prolong the life and performance of your product, we recommend that you only specify Francis Searchlights spare parts. This will ensure that any warranties on your equipment will not be invalidated. When ordering spare parts please contact the Sales Department at Francis Searchlights Limited.
Need help?
Do you have a question about the L560 and is the answer not in the manual?
Questions and answers