www.aeg.com
The minimum distance between the
supporting surface for the cooking
equipment on the hob and the lowest part
of the range hood must be not less than
60cm from electric cookers and 65cm from
gas or mixed cookers. If the instructions for
installation for the gas hob specify a greater
distance, this must be adhered to.
4. CONTROLS
The hood is fitted with a control panel with
aspiration speed selection control and a
light switch to control cooking area lights.
1. ON/OFF lighting
2. OFF motors
3. - 4. - 5. Minimum suction power (3.),
medium (4.), maximum (5.).
Use the high suction speed in cases
of concentrated kitchen vapours. It is
recommended that the cooker hood suction
is switched on for 5 minutes prior to cooking
and to leave in operation during cooking
and for another 15 minutes approximately
after terminating cooking.
2
1
3
5. LIGHTING
Disconnect the hood from the electricity.
Warning! Prior to touching the light bulbs
ensure they are cooled down.
Remove the damaged light and replace it
with a new one (see the table below):
4
5
Lamp
Power (W)
3
Voltage (V)
Dimension (mm)
220-240
(Diameter x Lenght)
ILCOS D Code
(according IEC 61231)
DRBB/C-3-220-240-E14-35/102
Socket
E14
35x102