Electrical Adjustments - Sony CDX-626 Quick Start Manual

Compact disc changer
Hide thumbs Also See for CDX-626:
Table of Contents

Advertisement

Note:
1. Perform adjustments as given.
2. Power supply voltage: DC14.4 V (more than 3A).
• FOCUS BIAS CHECK
[RF BOARD] – Conductor Side –
oscilloscope
CNJ12
TP (RF)
TP
(VC)
IC11
Procedure:
1. Connect the oscilloscope to TP (RF) and TP (VC) on the RF
board.
2. Put the set into play mode by loading the disc.
3. Confirm that oscilloscope waveform is clear and check RF
signal level is correct or not.
Note:
Clear RF signal waveform means that the shape "≈" can be clearly distin-
guished at the center of the waveform.
RF signal waveform
SECTION 6

ELECTRICAL ADJUSTMENTS

+
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
level: 1.4 ± 0.3 Vp-p
• TRACKING OFFSET CHECK
[RF BOARD] – Conductor Side –
CNJ12
BP11
(TE)
TP
(VC)
IC11
Procedure:
1. Connect the oscilloscope to BP11 (TE) and TP (VC) on the
RF board.
2. Put the set into play mode by loading the disc.
3. Press the = AMS + button, and check the traverse wave-
form*.
4. Confirm that the oscilloscope waveform is symmetrical on the
top and bottom in relation to 0 V dc, and check this level.
* Traverse waveform: This is the tracking error wave form appears
Traverse waveform
A
0 V
B
A=B
traverse waveform
(100 track jump waveform)
– 15 –
oscilloscope
+
when crossing the track.
VOLT/DIV : 500 mV
TIME/DIV : 2 ms
Center : 0 V