  • Page 1 Temperature & Humidity​ Sensor TBHH100-915 Reference Manual TBHH100-868...
  • Page 2: Table Of Contents

    6.2 PE Bag & Back Label Label Barcode 7. Important Product & Safety Instructions 8. Warnings 9. Notices 10. Cautions 11. Regulatory Appendix. Configuration Downlink Command Appx. 1 Payload Appx. 2 Response Content © 2019 Browan Communications Inc. All rights reserved.
  • Page 3: Specifications

    US: +19dBm LEDs One blue LED EU: +17dBm Rx Sensitivity -135dBm 2.7 Additional Features Antenna Gain -2dBi Peak, -5dBi Avg. Battery Monitoring 2.4 Certifications and Conformity FCC ID: 2AMUGTBSP100 IC: 22980-TBSP100 ROHS REACH © 2019 Browan Communications Inc. All rights reserved.
  • Page 4: Operation

    LoRaWAN Packets for this device use port 107. 4.1 Status 4.1.1 Triggers Packet Triggers: 60-minute inactivity, ±2 °C delta, ±5 %RH Delta 4.1.2 Payload Port Payload Length 8 bytes Bytes Field Status Battery Temp. CO​ (environment) © 2019 Browan Communications Inc. All rights reserved.
  • Page 5: Payload (Continue)

    Total Volatile Organic Compound Level as measured by the digital sensor Bits [15:0] The value is always displayed as 0xffff because no VOC sensor is installed in this module. © 2019 Browan Communications Inc. All rights reserved.
  • Page 6: Battery

    Replace only with the same or equivalent type recommended by the manufacturer. Discard used batteries according to the manufacturer’s instructions. Risk of Explosion if Battery is replaced by an Incorrect Type. Dispose of Used Batteries According to the Instructions. © 2019 Browan Communications Inc. All rights reserved.
  • Page 7: Label Format Information

    Uses a hexadecimal representation resulting in 16 characters. 6.1.3 DevEUI 58A0CBFFFFFEFFFF. Uses a hexadecimal representation resulting in 16 characters 6.1.4 Model number Non-reserved characters(except ":" and space) with a maximum length of 20 characters. © 2019 Browan Communications Inc. All rights reserved.
  • Page 8: Factory Check Code

    ● The GS1 Application Identifier (21) indicates that the GS1 Application Identifier data field contains a serial number. ● The GS1 Application Identifier (92) assigned to the company’s internal information is DevEUI. © 2019 Browan Communications Inc. All rights reserved.
  • Page 9: Important Product & Safety Instructions

    (whether integrated or removable) can cause an explosion or fire. ● Do not dry the sensors or battery with an external heat source such as a microwave oven or hairdryer. © 2019 Browan Communications Inc. All rights reserved.
  • Page 10: Warnings

    If contact has been made, wash the affected area with copious amounts of water and seek medical advice. ● Do not use any charger other than that specifically provided for use with the equipment. © 2019 Browan Communications Inc. All rights reserved.
  • Page 11: Notices

    ​ E XPLOSION​ or Incorrect Type. Dispose of Used Batteries According leakage of flammable liquid or gas. to the Instructions. Discard used batteries according to the manufacturer's instructions. © 2019 Browan Communications Inc. All rights reserved.
  • Page 12: Regulatory

    11. Regulatory Hereby, Browan Communications Inc. declares that the radio equipment for Tabs products is in compliance with Directive 2014/53/EU. This device complies with Part 15 of the FCC Rules and RSS Standards of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 13: Appendix. Configuration Downlink Command

    02 ​ 0 2​ => ​ T emperature trigger value​ : 0x02 -> 2 (​ ° C​ 03 ​ 0 5​ => ​ H umidity trigger value : ​ 0 x05 -> 5 (%RH) © 2019 Browan Communications Inc. All rights reserved.
  • Page 14: Appx. 2 Response Content

    02 ​ 0 2​ => ​ T emperature trigger value​ : 0x02 -> 2 (​ ° C​ 03 ​ 0 5​ => ​ H umidity trigger value : ​ 0 x05 -> 5 (%RH) 806b => Payload check byte: ​ R FU © 2019 Browan Communications Inc. All rights reserved.