A.O. Smith 120 trough 500 Service Handbook page 31

Series 100-109
Table of Contents

Advertisement

TROUBLESHOOTING THE EFFIKAL STYLE DAMPER
Condition:
Thermostat closed, damper
Wires are from left to right:
Black i Yellow i Brown i White
STEP A1
IF
24VAC is present
24VAC is not present
Condition:
Thermostat closed, damper in process of opening.
STEP A2
IF
24VAC is present
24VAC is not present
A.O. Smith Water Products
Irving, Texas ©2000
BTR TANK TYPE HEATERS
SERVICE HANDBOOK
TEST BETWEEN BLACK (COMMON) AND BROWN
ON THE DAMPER BOARD
TEST FOR 24VAC BETWEEN BLACK AND ORANGE
30
THEN
This is correct
See Steps 1 thru 4
Check the harness plugs connecting heater
and damper for looseness or damage.
THEN
This is correct
See Step 7
Check the harness plug connecting
heater ----or damaged
Service Handbook
Training Department

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents