Preliminary Check:
Symptom:
Red 'Power-On' Neon
- not lit
Red 'Power-On' Neon - lit
Water in the cylinder
No current
Red 'Power-On' Neon - lit
Water at top of the cylinder
and low current
Minivap Model
Output Range
Max Output
Power Rating
Electrical Supply 1Ø 60 Hz
Full Load Current
Fuse Rating
Height
Width
Depth
Service Weight
RDU Height
RDU Weight
Steam Pipe/Nozzle
Steam Hose Diameter
Control System
- On/Off
Steam Hose
Steam Hose Length
Condensate Hose
Water Connection
Drain Connection
Minivap Trouble-shooting Check-List
-Use manual drain switch to check pump operation (On/Off switch in 'off position)
Check/cause/remedy
-Check main power is connected and switched on.
-Check security circuit is complete (fan interlock, high humidity override).
-Check power supply fuses.
-Check Power-On neon.
-Check the switch is in the position marked 1 (unit On position).
-Check Minivap internal control circuit fuse.
-Check humidistat.
-Minivap automatic STOP function has operated for one of the following reasons:
a) Feed Fault STOP
b) Drain Fault STOP
c) High Overcurrent STOP
If no obvious Feed Fault condition (a) exists, i.e. no water in cylinder, assume that (b)
or (c) applied. Carry out full inspection of cylinder and drain pump. Switching the unit
Off and On again cancels the automatic STOP condition but user should not put unit
back into service until the above action has been taken and the cause of the
interruption remedied.
-Slow start-up situation with a new cylinder. Low conductivity (soft) water. Add Alka
Seltzer to boost conductivity of the water. If above action is not successful and
condition returns, an alternative lower resistance cylinder may be necessary
-Reduced output due to scale deposits,.
Remove cylinder for rinsing out and re-use or fit a new replacement cylinder.
kg/h
lb/h
kg/h
lb/h
kW
Volts
Amps
Amps
mm
mm
mm
kg
mm
kg
No.
mm
-
internal diameter 22mm (7/8")
-
recommended maximum 2m with continuous fall back to, the Minivap unit.
-
internal diameter 6mm (1/4")
-
3/4" threaded connection to Minivap feed valve - use flexible connector supplied with
unit which (underside) has VC threaded nylon nut at each end.
-
has connection size 35mm (1 3/4") diameter unthreaded - use short length of hose to
interconnect (underside) onto copper pipe and discharge drain water to one side of
unit into an open tundish.
LDV4
1.5 – 2.75
2.75 – 5.5
3 – 6
2.75
6
2.1
120
19
25
500
325
230
16
185
3.5
9
LDV4-S
6 – 12
5.5
12
4.2
240
19
25
(19¾")
(12¾")
(9")
(35 lb)
(7¼")
(8 lb)
1
22
208
19
25

Advertisement

loading

This manual is also suitable for:

Minivap ldv4-s