Characteristics
• The smoke detector is used for the early warning of an emerging fi re in residential
and commercial buildings and also measures the actual temperature, humidity
and light intensity in the room.
• The detector utilises a scanning method using an optical chamber, which has en-
hanced smoke detection responses.
• Self-test function highlights the failure of the detector, eliminating the malfunc-
tion in the event of a fi re.
• Anti-sabotage: If access to the device is unauthorized, a message is immediately
sent to the server.
• Thanks to the wireless solution and Sigfox communication, it can communicate
instantly to your chosen location and be operated immediately.
• Data is sent to the server from which it can be subsequently displayed as a smart-
phone, application, or Cloud notifi cation.
• Battery power can be sent to the server when it is powered by a battery.
• Power supply: battery 4 x 1.5 V AA, the battery life is around 1 year.
Description
1
2
3
3
2
1
The underside of
the detector
4
4
The inner side of
the base
Cloud app assignment
It is done in your Smartphone application. Enter the relevant data located on the detec-
tor cover into the application.
5
2
3
6
1
7
2
The front of the
detector
4
1. Two-color LED position
2. Holes for locking segments
3. Battery
4. Secure segments
5. DIP switch - Position 1 - Turn off
scanning signaling
8
6. Button SET
7. Tamper position
4
8. Probe for magnet scanning
tampermenty
AirSD-100S
Smoke detector
General instrucions
Internet of Things (IoT)
• The IOT wireless communications category describes the Low Power Wide Area
(LPWA). This technology is designed to provide full-range coverage both inside and
outside buildings, energy-saving and low-cost operation of individual devices. The
Sigfox network is available to use this standard.
Sigfox network information
• The network supports bidirectional communication but with a limited number of feed-
backs. It uses the free frequency band divided by Radio Frequency Zones (RCZ).
RCZ1 (868 MHz) Europe, Oman, South Africa
RCZ2 (902 MHz) North America
RCZ3 (923 MHz) Japan
RCZ4 (920 MHz) South America, Australia, New Zealand, Singapore, Taiwan
• Sigfox has more coverage across countries, so it is better suited for long distance mo-
nitoring.
• For more information on this technology, please visit www.sigfox.com.
Caution for proper operation:
• Products are installed according to the wiring diagram given for each product.
• For proper device functionality, it is necessary to have suffi cient coverage of the selec-
ted network at the installation site.
• At the same time, the device must be registered in the network. Successful device re-
gistration on a given network requires a charge for traffi c.
• Each network off ers diff erent tariff options - it always depends on the number of me-
ssages you want to send from your device. Information on these tariff s can be found in
the current version of the ELKO EP pricelist.
Assembly
1
4
b)
1. Place the base at the desired location (on a fl at surface). You can use the base as a drilling
template. Attach the base with suitable bonding material * according to the substrate.
2. Insert the batteries into the detector and check that they are correctly positioned (a
detector functionality message will be sent to the application when the batteries are
inserted).
3. Set DIP 1 as required.
4. Attach the detector to the base so that the projection on the base faces the tamper posi-
tion in the detector cover (a). Turn the detector clockwise (b).
5. Press the test button to test the correct alarm function (see Test Detector Test).
* Suitable fi tting material can be, for example, a countersunk head screw, a screw Ø of
3 mm.
1 / 4
2
3
5
a)
EN

Advertisement

loading

Summary of Contents for Elko iNELS Air AirSD-100S

  • Page 1 • Each network off ers diff erent tariff options - it always depends on the number of me- ssages you want to send from your device. Information on these tariff s can be found in the current version of the ELKO EP pricelist. Assembly...
  • Page 2 Function Placement recommendations An internal, battery-powered smoke detector combines the timely detection of smoul- wall dering and open fi res from which smoke escapes. It is equipped with an optical smoke corner of the room detector for smoke detection. An example of a smouldering fi re is a burning cigarette on a couch or bedding, which is a common cause of fi res.
  • Page 3 Maintenance and cleaning Replacing batteries To ensure proper operation, it is advisable to keep the detector clean. 1. Rotate the detector counter clockwise and remove it from the base. 2. Remove the original battery and insert new batteries into the battery holder. Beware of •...
  • Page 4 * Values are calculated under ideal conditions and may vary according to alarm frequency ** Depending on network coverage The company ELKO EP, as the manufacturer, is entitled to make technical modifi cations to the product, in the technical specifi cation and product manual, without prior notifi cation.