Checking before use

Operation ranges
The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the
table for efficient use.
Mode
Indoor temperature
Cooling
Heating
Dry
If the air conditioner operates in cooling mode for long period of time in high humidity area, dew may be formed.
If the outdoor temperature goes down to -5°C, heating capacity may decrease as much as 60%~70% of
specified capacity according to the using conditions.
Model : RJ
Indoor
Mode
temperature
Cooling
16˚C~32˚C
Heating
27˚C or less
Dry
18˚C~32˚C
The standardizedtemperature for heating is 7˚C. If the outdoor temperature drops to 0˚C or below, the heating capacity can
be reduced depending on the temperature condition.
If the cooling operation is used at over 32˚C(indoor temperature), it does not cool at its full capacity.
Maintaining your air conditioner
Internal protections via the unit control system
This internal protection operates if an internal fault occurs in the air conditioner.
Type
Against cold air
De-ice cycle
Anti-protection of
internal battery
Protect compressor
• I f the heat pump is operating in Heat mode, De-ice cycle is actuated to remove frost from an outdoor unit that may
have deposited at low temperatures.
The internal fan is switched off automatically and restarted only after the de-ice cycle is completed.
6
AQV09K&Y@@_Jungfrau_IBIM_E_32448A.indd 6
Outdoor temperature
16˚C~32˚C
-10˚C~46˚C
27˚C or less
-15˚C~24˚C
18˚C~32˚C
-10˚C~46˚C
Outdoor
Indoor
temperature
humidity
-5˚C~46˚C
80% or less
-15˚C~24˚C
-
-5˚C~46˚C
-
The internal fan will be off to against cold air when the heat pump is heating.
The internal fan will be off to against cold air when the heat pump is heating.
The compressor will be off to protect internal battery when the air conditioner operates
in Cool mode.
The air conditioner does not start operating immediately to protect the compressor of
the outdoor unit after it has been started.
Relative humidity 80% or less
If out of conditions
Condensation may occur on the indoor unit with risk to have
either water blow off or drop on the floor.
Internal protection triggers and the air conditioner will stop.
Condensation may occur on the indoor unit with risk to have
either water blow off or drop on the floor.
Description
Indoor humidity
-
-