Technical Specifications; Power Connection; Installation In The Cabinet; Installation And Maintenance - Samsung BF3ON3T11G/XEU User Manual

Table of Contents

Advertisement

Installation & Maintenance
Safety instructions for the installation
EN
This oven may be installed only by an approved electrician. The installer is responsible for
connecting the appliance to the mains and in so doing for observing the relevant safety
regulations.
● Ensure protection from live parts when installing the oven.
● The kitchen cabinet in which the oven is built in must satisfy stability requirements as
specified in DIN 68930.

Technical Specifications

Input voltage / frequency
Volume (usable capacity)
Output rating
Net weight
Weight with packaging
Housing (W x H x D)
Oven interior (W x H x D)

Power Connection

If the appliance is not connected to the mains with a plug, a
multi-pole isolator switch (with at least 3 mm contact spacing)
must be provided in order to satisfy safety regulations. The
power cable (H05 RR-F or H05 VV-F, min. 1.5 m, 1.5 ~ 2.5
mm²) must be of sufficient length to be connected to the oven,
even if the oven stands on the floor in front of its built-in
cabinet. Open the rear connection cover of the oven with a
screwdriver and loosen the screws of the cable clamp before
you connect the power lines to the relevant connection
terminals. The oven is earthed via the (
oven is connected to the mains with
must remain accessible after the oven is installed. Samsung will
take no responsibility for accidents that originate from a missing or
faulty earth connection.

Installation in the Cabinet

This is a built-in oven, which needs to be installed into an upper or
lower cabinet.
● Observe minimum distances.
● Fix oven on both sides using screws.
After installation, remove the vinyl protective
film from the door to the appliance and the
protective film from the interior surfaces of
the oven.
BF3ON3T11_XEU-00069R-01.indd 4
230 V ~ 50 Hz
65 L
max. 3400 W
approx. 33 kg
approx. 37 kg
595 x 595 x 566 mm
440 x 365 x 405 mm
)-terminal. If the
a plug, this plug
min.550
min.600
min.560
Air flow
4
min. 550
min. 590
max. 600
min. 560
Upper Cabinet
min. 550
min. 50
min. 600
min. 560
Lower Cabinet
min. 50
min. 50
2011-02-17
11:55:01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bf3on3t11p/xeuBf3on3t11

Table of Contents