Polaris PGC 34-100-2NV Installation Instructions And Use & Care Manual page 21

Commercial gas water heater
Table of Contents

Advertisement

WIRING DIAGRAM
HEATER SUPPLIED WITH T92 SERIES RELAY
Figure 20A
BROWN
THERMOSTAT
SENSOR/ECO
GAS VALVE
BROWN
RED
LED
THERMOSTAT
BOARD
YELLOW
YELLOW
LED
COM
RED
RELAY
GREEN
NO
LED
ORANGE
THERMOSTAT
NOTICE: IF ANY OF THE ORIGINAL WIRE
DIAL
AS SUPPLIED WITH THE APPLIANCE
MUST BE REPLACED, IT MUST BE
REPLACED WITH 18 GAUGE STRANDED
105C WIRE OR ITS EQUIVALENT.
HEATER SUPPLIED WITH KUHP SERIES RELAY
Figure 20B
BLUE
RED
RED
RED
GREEN
RED
BLACK
IGNITER
POT
YELLOW
SEN-1
RED
LOWER
GREEN
GREEN
24V
HOT
ONLY
YELLOW
BLACK
WHITE
WHITE
GREEN
GROUND
GREEN
RELAY
DISCONNECTED
1
0
8
6
BLACK
BLACK/RED
WHITE
(BLACK & WHITE
IND
WIRES IN BOLD)
L1
HSI
WHITE
HSIG
L2
IGNITION
CONTROL
W
PSI
120V/60Hz
GV
PSO
FSG
C
WHITE
BLUE
ORANGE
FUSED
BLOWER
DISCONNECT
N.O.
BLACK
6
8
RELAY
NEUTRAL (WHITE)
TO 120/60
POWER
SUPPLY
L1 (BLACK)
FUSED
120 VAC
PRESSURE
SWITCH
COMMON (C)
YELLOW LED
PRESSURE
SWITCH
GND
NORMALLY OPEN
(NO)
NEUTRAL
L1
TO 120/60
POWER SUPPLY
GND
BLOWER
GND
GND
L2
0
1
WHITE
BLACK/WHITE
RELAY
COIL
IND
L2
HSI
L1
IGNITION
IGNITER
CONTROL
HSIG
120 VAC
24 VAC
GREEN LED
PSI
C
GAS VALVE
PSO
RELAY
IGNITION
GV
CONTROL
W
THERMOSTAT
SENSOR-ECO
RED LED
N.O.
SEN-1
COM
LOWER
THERMOSTAT
24 V
BOARD
HOT
THERMOSTAT
POT
ONLY
DIAL
GND