Product Identification - Lennox Hearth Products SUPERIOR SVFS32NEVF Owner's Operation And Installation Manual

Unvented (vent-free) gas fireplace
Table of Contents

Advertisement

3. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not
use any phone in your building
• immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions
• if you cannot reach your gas supplier,
call the fire department
4. This fireplace shall not be installed in a
bedroom or bathroom.
5. Do not use this fireplace as a wood-burn-
ing fireplace. Use only the logs provided
with the fireplace.
6. Do not add extra logs or ornaments such
as pine cones, vermiculite, or rock wool.
Using these added items can cause soot-
ing. Do not add lava rock around base.
Rock and debris could fall into the control
f i r e - p a r t s . c o m
area of fireplace.
7. To prevent the creation of soot, follow the
instructions in Cleaning and Maintenance,
page 31.
8. Before using furniture polish, wax, carpet
cleaner, or similar products, turn heater
off. If heated, the vapors from these prod-
ucts may create a white powder residue
within burner box or on adjacent walls or
furniture.
9. This fireplace needs fresh air ventilation to
run properly. This fireplace has an Oxygen
Log Set
Remote
Control
Figure 1 - Log Base Assembly
4

PRODUCT IDENTIFICATION

Base
Front
Assembly
Burner
www.lennoxhearthproducts.com
SAFETY
Continued
Depletion Sensing (ODS) safety shutoff
system. The ODS shuts down the fire-
place if enough fresh air is not available.
See Air for Combustion and Ventilation,
page 6. If fireplace keeps shutting off, see
Troubleshooting, page 33.
10. Do not run fireplace
• where flammable liquids or vapors are
used or stored
• under dusty conditions
11. Do not use this fireplace to cook food or
burn paper or other objects.
12. Do not use fireplace if any part has been
exposed to or under water. Immediately
call a qualified service technician to in-
spect the fireplace and to replace any part
of the control system and any gas control
which has been under water.
13. Do not operate fireplace if any log is
broken. Do not operate fireplace if a log
is chipped (dime-sized or larger).
14. Turn fireplace off and let cool before
servicing. Only a qualified service person
should service and repair fireplace.
15. Operating fireplace above elevations of
4,500 feet could cause pilot outage.
16. To prevent performance problems in
propane/LP units, do not use propane/LP
fuel tanks of less than 100 lbs. capacity
(propane/LP units only).
17. Provide adequate clearances around air
openings.
Top panel
Assembly
Fireplace
Hood
Magnet
Screen
Assembly
Top Outer Casing
Bottom Panel
Assembly
Figure 2 - Fireplace
126544-01A

Advertisement

Table of Contents
loading

Table of Contents