LG LFX2597 Series Service Manual page 28

Table of Contents

Advertisement

8-7 Icing Fan Error (Er IF)
No
1
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
2
Open the refrigerator door and Check the
air flow.
※ While an error code is displayed,
the fan is not working.
3
Check the Connector.
(Frozen caused the PCB short)
4
Check the Fan motor.
(Frozen, Lock, ect.)
5
Check the Fan motor voltage.
C O N7
< M ain>
Checking flow
(1)Pin1, (2)Pin3, (3)Pin5
<CON7>
Result & SVC Action
※ Tip
To protect ice short, add wire seal in
connector. We developed new type
connector, so order the new type.
Wire seal (silicon)
No
Part Name
Duct Asm,
407A
Connector
Point
(2) ~ (3)
Below 7 V
(1) ~ (3)
- 28 -
Status
SVC Action
No windy
Go to the 3,4
Windy
Go to the 5
Old P/No
New P/No
5209JA
5209JA
1044A
1044A
Result
SVC Action
Change the PCB
0 or 5 V
Change the motor

Hide quick links: