Page 1
1 data signal plus full duplex 100BaseT Ethernet connectivity over two Singlemode fibres. The AMG4783ER is designed to plug into an AMG2005 or AMG2009 subrack, which in turn fits into a 19" rack system. The AMG4783ER is designed to operate with AMG4784E or rackmount equivalent AMG4784ER eight channel video receive unit in a point to point configuration.
Removal / replacement from / to the Case..................8 Safety Maintenance and Repair AMG Systems Ltd. reserves the right to make changes to this Page 2 of 8 AMG4783ER Instruction Sheet document without notice. The information herein is believed to D18106-01.doc...
Ethernet connectivity is also provided between the two units. Optical Connection The AMG4783ER is connected as illustrated below when used with an AMG4784ER 8-channel receive unit acting as a point to point system. AMG Systems Ltd. reserves the right to make changes to this...
RS485 – switch position – low (furthest from BNC connections) DATA CHANNEL B Data Channel B ........Not Present AMG Systems Ltd. reserves the right to make changes to this Page 4 of 8 AMG4783ER Instruction Sheet document without notice. The information herein is believed to D18106-01.doc...
RS485 bus high (+5 volts) and the other arm low (0 volts) using high value resistors within the third party equipment. In order to ensure that the AMG equipment detects a tri-state condition, then these resistors should have a value above 5kΩ. If the third party bias resistors are less the 750Ω...
OUT+ logic one (-V) present on OUT+ This represents the data signals being received on the optical fibre AMG Systems Ltd. reserves the right to make changes to this Page 6 of 8 AMG4783ER Instruction Sheet document without notice.
Ethernet Operation In order for the AMG system to transmit Ethernet signals, an onboard RJ45 Ethernet interface or X16003 Ethernet interface adaptor should be fitted to both the Transmit unit and the Receive unit. The Ethernet interface can operate at either 10Mbits/s half duplex, or 100Mbit/s full duplex, and data is transmitted from one port the other port with the minimum of delay or buffering.
There are no user serviceable parts within AMG products. See unit data sheet for full specification. In case of problem or failure, please call your local support centre or contact: AMG Systems Ltd. at 3 The Omega Centre, Stratton Business Park, Biggleswade, Beds., SG18 8QB, UK.