Download Print this page
Honeywell ZW4009 Quick Start Manual

Honeywell ZW4009 Quick Start Manual

Advertisement

Quick Links

FCC/IC - EN
This device complies with Part 15 of the FCC and Industry Canada license-exempt
RSS standards. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
FCC NOTE: The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications to this equipment. Such
modifications could void the user's authority to operate the equipment
NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy, and if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different to which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
Important note: To comply with the FCC RF exposure compliance requirements,
no change to the antenna or the device is permitted. Any change to the
antenna or the device could result in the device exceeding the RF exposure
requirements and void user's authority to operate the device.
FCC /IC - FR
Cet appareil est conforme au paragraphe 15 des normes FCC et au CNR pour les
appareils exempts de licence d'Industrie Canada. Son utilisation est sujette aux
deux conditions suivantes (1) cet appareil ne doit pas occasionner de brouillage
préjudiciable et (2) cet appareil doit accepter toutes les interférences reçues,
notamment les interférences qui peuvent provoquer un fonctionnement non désiré.
REMARQUE DE LA FCC : Le fabricant n'est pas responsable des interférences
sur les fréquences radioélectriques ou télévisuelles pouvant être causées
par des modifications non autorisées de ce matériel. De telles modifications
peuvent annuler le droit de l'utilisateur à utiliser cet appareil.
REMARQUE : Cet appareil a été testé et certifié conforme aux limites relatives aux appareils
numériques de catégorie B définies dans le paragraphe 15 des normes FCC. Ces limites ont
été définies afin de fournir une protection raisonnable contre le brouillage préjudiciable en
milieu résidentiel. Cet appareil produit, utilise et peut émettre des ondes de fréquence radio et,
s'il n'est pas installé et utilisé conformément aux instructions, il peut provoquer un brouillage
préjudiciable aux communications radio. Il n'existe toutefois aucune garantie que des
interférences ne se produiront pas dans une installation donnée. Si cet appareil occasionne
un brouillage préjudiciable à la réception radiophonique ou télévisuelle, il suffit d'allumer
et d'éteindre l'appareil pour déterminer sa responsabilité. Nous encourageons l'utilisateur à
essayer de corriger ces interférences en appliquant une ou plusieurs des mesures suivantes :
— Réorienter ou déplacer l'antenne de réception.
— Augmenter la distance entre l'appareil et le récepteur.
— Brancher l'appareil à une prise secteur différente de celle du récepteur.
— Pour obtenir de l'aide, consulter le revendeur ou un technicien
spécialisé en postes radio ou téléviseurs.
Remarque importante : Pour se conformer aux exigences de conformité de la
FCC concernant l'exposition aux RF, aucune modification apportée à l'antenne
ou au dispositif n'est autorisée. Toute modification apportée à l'antenne ou au
dispositif pourrait faire en sorte que le dispositif dépasse les exigences d'exposition
aux RF et pourrait annuler le droit de l'utilisateur à utiliser ce dispositif.
FCC/IC - ES
Este dispositivo cumple con las Especificaciones del apartado 15 de las normas de
la FCC y con las especificaciones de las normas radioeléctricas (RSS) del Ministerio
de Industria de Canadá aplicables a aparatos exentos de licencia. El funcionamiento
está sujeto a las siguientes dos condiciones: (1) este dispositivo no debe provocar
interferencia perjudicial, y (2) este dispositivo debe aceptar toda interferencia
que reciba, incluso la que pudiera causar un funcionamiento no deseado.
NOTA DE LA FCC: El fabricante no se hace responsable de ninguna interferencia de
radio o TV ocasionada por modificaciones no autorizadas efectuadas a este equipo.
Dichas modificaciones podrían anular la autoridad del usuario para utilizar el equipo.
NOTA: Este equipo ha sido probado y cumple con los límites para aparatos digitales
de Clase B, de conformidad con el apartado 15 de las normas de la FCC. Estos límites
están diseñados para proveer protección razonable contra interferencias perjudiciales
en una instalación residencial. Este equipo genera, usa y puede irradiar energía de
radiofrecuencias y, si no se instala y usa según las instrucciones, puede provocar
interferencia perjudicial a las radiocomunicaciones. No obstante, no hay garantías de
que no ocurrirá interferencia en una instalación en particular. Si este equipo provoca
interferencia perjudicial a la recepción de radio o televisión, lo que puede determinarse
encendiendo y apagando el equipo, se recomienda que el usuario intente corregir la
interferencia por medio de la implementación de una o más de las siguientes medidas:
— Reorientar o reubicar la antena receptora.
— Incrementar la separación entre el equipo y el receptor.
— Conectar el equipo a un tomacorriente de un circuito diferente
del circuito al que está conectado el receptor.
— Consultar al distribuidor o a un técnico con experiencia en radio/televisión para
solicitar asistencia.
Nota importante: Para cumplir con los requisitos de cumplimiento de exposición de
radiofrecuencia de la FCC, no se permiten cambios a la antena o el dispositivo. Cualquier
cambio a la antena o dispositivo podría hacer que el dispositivo supere los requerimientos de
exposición de radiofrecuencia y anular la autoridad del usuario para operar el dispositivo.
FCC — U2ZZW4009 | IC: 6924A-ZW4009
Jasco Products Company | Model: ZW4009/39354
CAN ICES-3(B)/NMB-3(B)
All brand names shown are
Tous les noms de marque illustrés
Todas las marcas que aparecen
trademarks of their respective owners.
sont des marques de commerce
aquí son marcas registradas
de leurs propriétaires respectifs.
de sus respectivos dueños
The Honeywell Trademark is used under license
from Honeywell International Inc.
Honeywell International Inc. makes no representation or warranties with
respect to this product.
This product is manufactured by Jasco Products Company LLC.
MADE IN CHINA/FABRIQUÉ EN CHINE/HECHO EN CHINA
©JASCO 2019 | 39354 | ZW4009 | 5/10/19 v1
Jasco Products Company LLC.
10 E. Memorial Rd.,
Oklahoma City, OK 73114
1
TOOLS
IMPORTANT!
The fixture controlled by the Honeywell In-Wall Smart Switch must not exceed 960W
incandescent; 1800W (15A) resistive or 1/2HP motor. The switch is designed only for use with
permanently installed fixtures.
2
FEATURES
• Turn ON/OFF manually or remotely via the Z-Wave controller
• Can be added in multiple groups and scenes
• May be used in single-pole installation or with up to five Honeywell
add-on switches in 3-way wiring configurations
• Compatible with all incandescent and CFL/LED bulbs
• Uses a standard, toggle-style wallplate for single-gang installations
(wallplate not included)
• Z-Wave certified for simple pairing and integrated home automation
• Screw terminal installation — requires wiring connections for line (hot),
load, neutral and ground. Traveler wire required for 3-way or installation
• This Z-Wave device has advanced features that allow you to customize
your experience. These features can only be adjusted by a Z-Wave enabled
controller that supports the Z-Wave configuration command class. For a
complete list of adjustable configurations, visit
www.honeywellelectricalaccessories.com
A
D
B
F
G
E
C
A.
Ground (Green/Bare)
F.
Up — Press & release to turn
switch on
B.
Line or Load (Black)
G.
Down — Press & release to
C.
Line or Load (Black)
turn switch off
D.
Traveler (Red/Other)
E.
Neutral (White)
READ IT OR WATCH IT
Read instructions or watch easy-to-follow
video. Scan QR code or visit goo.gl/jdggfo
SMART SWITCH
IN-WALL
INTERRUPTEUR INTELLIGENT
DANS LE MUR
INTERRUPTOR INTELIGENTE
DE LA PARED
Z-W
® C
W
L
C
AvE
ERTIFIED
IRELEss
IGHTInG
OnTROL
Z-W
® C
I
I
AvE
OnTROL DE
LUMInACIón
nALáMBRICO CERTIFICADO
C
Z-W
®
OnTROL InALáMBRICO pARA ILUMInACIón CERTIFICADO pOR
AvE
Purchase additional items at
Purchase additional items at
Purchase additional items at
honeywellelectricalaccessories.com
honeywellelectricalaccessories.com
honeywellelectricalaccessories.com
or visit your local retailer.
or visit your local retailer.
or visit your local retailer.
In-Wall
In-Wall
In-Wall
Plug-in
Plug-in
Plug-in
Smart Switches
Smart Switches
Smart Switches
Smart Swtiches
Smart Swtiches
Smart Swtiches
Plug-in
Plug-in
Plug-in
In-Wall
In-Wall
In-Wall
Smart Dimmers
Smart Dimmers
Smart Dimmers
Smart Dimmers
Smart Dimmers
Smart Dimmers
In-Wall
In-Wall
In-Wall
Plug-in
Plug-in
Plug-in
Smart Fan Control
Smart Fan Control
Smart Fan Control
Outdoor
Outdoor
Outdoor
Smart Switch
Smart Switch
Smart Switch
In-Wall
In-Wall
In-Wall
In-Wall
In-Wall
In-Wall
Add-on Switches
Add-on Switches
Add-on Switches
Tamper-Resistant
Tamper-Resistant
Tamper-Resistant
Smart Outlet
Smart Outlet
Smart Outlet
3
INSTALLATION
1
1
2
3
OUT TO
LIGHT (LOAD)
B
A
D
E
C
5
7
FROM BREAKER BOX
OUT TO LIGHT (LOAD)
A
B
D
E
C
FROM BREAKER BOX
8
9
10 11
12 13
14
DO NOT RETURN THIS
PRODUCT TO THE STORE
NE RETOURNEZ PAS CE
STOP
PRODUIT AU MAGASIN
NO DEVUELVA ESTE
PRODUCTO A LA TIENDA
Questions? Contact our U.S.-based Consumer Care at
1-855-698-8324 between 7AM-8PM CST.
For the most up-to-date product support, accessories, electronic
(PDF) format manuals and more, visit www.byjasco.com/support.
• No user-serviceable parts in this unit.
Si vous avez des problèmes ou des questions, communiquez
avec notre équipe de soutien technique au 1-855-698-8324,
option 1, du lundi au vendredi, de 7 h à 20 h (HNC).
Pour le soutien relatif aux produits le plus à jour, les
accessoires, les manuels en format électronique (PDF) et
plus encore, visitez le site www.byjasco.com/support.
• Aucune des pièces de ce dispositif ne peut être réparée par l'utilisateur.
Si tiene problemas o dudas, comuníquese con nuestro equipo
técnico al número: 1-855-698-8324, opción 1 de lunes a viernes,
de 7 a.m. a 8 p.m., hora estándar del centro (CST).
Para recibir el soporte técnico más actualizado sobre productos, accesorios,
manuales en formato digital (PDF), entre otros, visite www.byjasco.com/support.
• Esta unidad no contiene piezas que el usuario pueda reparar.
WARNING
ADVERTENCIA
RISK OF FIRE
RIESGO DE INCENDIO
RISK OF ELECTRICAL SHOCK
RIESGO DE DESCARGA ELÉCTRICA
RISK OF BURNS
RIESGO DE QUEMADURAS
CONTROLLING APPLIANCES
CONTROL DE APARATOS
CAUTION:
PRECAUCIÓN:
• DO NOT EXCEED RATINGS
• NO SUPERAR LOS VALORES
NOMINALES ELÉCTRICOS
• DO NOT USE TO CONTROL ANY DEVICE
WHERE UNINTENDED OPERATION
• NO USAR PARA CONTROLAR
COULD CAUSE UNSAFE CONDITIONS
DISPOSITIVOS EN LOS QUE
(HEAT LAMP, SUN LAMP, ETC.)
EL FUNCIONAMIENTO NO
INTENCIONADO PODRÍA PROVOCAR
• DO NOT USE TO CONTROL
SITUACIONES PELIGROSAS
RECEPTACLES
(LÁMPARAS DE CALEFACCIÓN,
• FOR INDOOR USE ONLY
39354
LÁMPARAS SOLARES, ETC.)
ZW4009
AVERTISSEMENT
• NO UTILIZAR EL DISPOSITIVO PARA
CONTROLAR TOMACORRIENTES
• PARA USO EN INTERIORES
RISQUE D'INCENDIE
EXCLUSIVAMENTE
RISQUE DE CHOC ÉLECTRIQUE
RISQUE DE BRÛLURES
COMMANDE DES APPAREILS
NOT FOR USE WITH MEDICAL OR
ATTENTION :
LIFE-SUPPORT EQUIPMENT
Z-WAVE ENABLED DEVICES SHOULD
• NE PAS DÉPASSER LES
NEVER BE USED TO SUPPLY
CARACTÉRISTIQUES NOMINALES
POWER TO, OR CONTROL THE ON/
• NE PAS UTILISER POUR COMMANDER
OFF STATUS OF MEDICAL AND
DES APPAREILS POUR LESQUELS
LIFE-SUPPORT EQUIPMENT.
UN FONCTIONNEMENT IMPRÉVU
POURRAIT ENTRAÎNER DES
NE PAS UTILISER AVEC UN
CONDITIONS DANGEREUSES (LAMPE
ÉQUIPEMENT MÉDICAL
INFRAROUGE, LAMPE SOLAIRE, ETC.)
OU DE SURVIE
• NE PAS UTILISER POUR COMMANDER
LES DISPOSITIFS COMPATIBLES
DES PRISES DE COURANT
AVEC LA TECHNOLOGIE Z-WAVE NE
DEVRAIENT JAMAIS ÊTRE UTILISÉS
• POUR UTILISATION INTÉRIEURE
POUR ALIMENTER OU COMMANDER
UNIQUEMENT
LA MISE EN MARCHE OU L'ARRÊT DE
L'ÉQUIPEMENT MÉDICAL OU DE SURVIE.
SE PROHÍBE SU EMPLEO EN
EQUIPO MÉDICO O EQUIPO
PARA EL MANTENIMIENTO DE
LAS FUNCIONES VITALES
LOS DISPOSITIVOS Z-WAVE NUNCA
SE DEBEN USAR PARA SUMINISTRAR
ENERGÍA ELÉCTRICA, NI PARA
CONTROLAR EL ESTADO DE ENCENDIDO
O APAGADO DEL EQUIPO MÉDICO Y/O
EL EQUIPO PARA EL MANTENIMIENTO
DE FUNCIONES VITALES.
WARNING — SHOCK HAZARD
Turn OFF the power to the branch circuit for the switch and lighting fixture at the service
panel. All wiring connections must be made with the POWER OFF to avoid personal injury and
damage to the switch. This device is intended for installation in accordance with the National
Electric Code and local regulations in the United States or the Canadian Electrical Code
and local regulations in Canada. If you are unsure or uncomfortable about performing this
installation, consult a qualified electrician.
MULTI-SWITCH WIRING
The Honeywell Add-on Switch is required for multi-switch installations.
Connecting the traveler terminal of this switch to a standard, non-Honeywell
switch will cause damage or result in improper function. If this switch is a
part of a 3-way or 4-way multi-switch installation, do not connect the traveler
wire or apply power until Honeywell Add-on Switches are correctly installed.
For more information on multi-switch installations, view the manual or
quick-start guide that comes with the Honeywell Add-on Switch.
IMPORTANT! Verify power is OFF to switch box before continuing.
SINGLE-SWITCH WIRING
1.
Shut off power to the circuit at circuit breaker or fuse box.
IMPORTANT! Verify power is OFF to switch box before continuing.
2.
Remove wallplate.
3.
Remove the switch mounting screws.
4.
Carefully remove the switch from the switch box. DO NOT disconnect
the wires.
5.
There are up to five screw terminals on the switch; these are marked:
A. GROUND — Green/Bare
B. LINE or LOAD — Black (connected to power or lighting)
C. LINE or LOAD — Black (connected to power or lighting)
D. TRAVELER — Red/Other (only in 3-way installations)
E. NEUTRAL — White
Match these screw terminals to the wires connected to the existing switch.
6.
Disconnect the wires from the existing switch. Label wires according to
the previous terminal connection.
OBSERVE IMPORTANT WIRING INFORMATION
IMPORTANT! This switch is rated for and intended to only be used with copper wire.
WIRE GAUGE REQUIREMENTS
Use 14AWG or larger wires suitable for at least 80° C for supplying line (hot),
load, neutral, ground and traveler connections.
WIRE STRIP LENGTH
7.
Use only the enclosure's holes - strip insulation 5/8in (16mm). Do not wrap
wires around screws.
UL specifies the tightening torque for the screws is
12lbf-in (14Kgf-cm).
8.
Connect the green or bare copper ground wire to the GROUND
terminal.
9.
Connect the black wire from the light to either LINE/LOAD terminal.
10.
Connect the black wire from the electrical service panel (hot) to the
other LINE/LOAD terminal.
11.
Connect the white wire to the NEUTRAL terminal (use a jumper wire if needed).
Note: The traveler terminal is only used for 3-way.
wiring and should remain insulated if the switch is being installed in a
single-pole installation (one switch & one load).
12.
Insert switch into the switch box being careful not to pinch or crush wires.
13.
Secure the switch to the box using the supplied screws.
14.
Mount the wallplate.
15.
Reapply power to the circuit at fuse box or circuit breaker and test
the system.
BASIC OPERATION
The connected light can be turned ON/OFF in two ways:
1.
Manually from the front panel of the in-wall switch.
2.
Remotely with a Z-Wave controller.
MANUAL CONTROL
The front panel toggle switch allows the user to turn ON/OFF the
connected fixture.
1.
To turn the connected fixture ON: Press up on the toggle switch
and release.
2.
To turn the connected fixture OFF: Press down on the toggle switch
and release..
CYCLE LED LIGHT
An LED shines behind the toggle to act as a guide light or status indicator.
How to cycle between options: Press up three
times, then down one time quickly
1.
LED is OFF all the time (default)
2.
LED is ON all of the time (illuminates switch in the dark)
3.
LED is ON when the load is OFF (guide light in the dark)
4.
LED is ON when the load is ON (indicates the switch is ON)
WARRANTY
Jasco Products Company warrants this product to be free from manufacturing defects
for two years from the original date of consumer purchase. This warranty is limited to
the repair or replacement of this product only and does not extend to consequential or
incidental damage to other products that may be used with this product. This warranty is
in lieu of all other warranties, expressed or implied. Some states do not allow limitations
on how long an implied warranty lasts or permit the exclusion or limitation of incidental
or consequential damage, so the above limitations may not apply to you. This warranty
gives you specific rights and you may also have other rights which vary from state to
state. Please contact Customer Service at 1-855-698-8324 between 7AM – 8PM CST
or via www.byjasco.com if the unit should prove defective within the warranty period.
GARANTIE
Jasco Products
Entreprise
garantit que ce produit est exempt de tout défaut de fabrication
pour une période de deux ans à compter de la date de l'achat original par l'acheteur. Cette
garantie se limite exclusivement à la réparation ou au remplacement de ce produit et n'est
pas applicable aux dommages indirects ou accessoires survenus sur d'autres produits
utilisés avec ce produit. Cette garantie se substitue à toute autre garantie expresse ou
implicite. Certains États ne permettent pas de restrictions quant à la durée d'une garantie
implicite ou permettent l'exclusion ou la limitation des dommages indirects et accessoires; il
se peut, par conséquent, que cette garantie ne s'applique pas dans votre cas. Cette garantie
vous confère des droits juridiques précis; vous pouvez jouir d'autres droits qui peuvent
varier d'un État à l'autre. Veuillez communiquer avec le service à la clientèle au 1-855-
698-8324 entre 7 h et 20 h (heure normale du Centre) ou par l'intermédiaire de notre site
web (www.byjasco.com) si l'appareil s'avère défaillant au cours de la période de garantie.
GARANTÍA
Jasco Products
Empressa
garantiza que este producto está libre de defectos de fabricación
durante un periodo de dos años a partir de la fecha original de compra por parte del
consumidor. Esta garantía se limita a la reparación o sustitución de este producto solamente
y no se extiende a daños derivados o accidentales causados a otros productos que se
usen con esta unidad. Esa garantía remplaza a todas las demás garantías expresas o
implícitas. Algunos estados no autorizan limitaciones en cuanto a la duración de una
garantía implícita ni permiten la exclusión o limitación por daños accidentales o derivados;
por lo tanto, puede que las anteriores limitaciones no apliquen en su caso. Esta garantía
le da a usted derechos específicos, y otros que usted puede tener y que varían según el
estado en el que usted reside. Si la unidad resultare defectuosa dentro del periodo de
garantía, comuníquese por favor con Atención al Cliente en el 855-698-8324 entre 7
y 20 h, Hora del Centro, o a través de nuestro sitio de internet (www.byjasco.com).
Jasco Products Company LLC, Building B
10 E. Memorial Rd. Oklahoma City, OK 73114.
SPECIFICATIONS
ZW4009
Power: 120VAC, 60Hz
Signal (frequency): 908.4/916MHz
Maximum loads: 960W incandescent, 1/2HP motor or 1800W (15A) resistive
Range: Up to 150ft. line of sight between the wireless controller
and the closest Z-Wave receiver module.
Operating temperature range: 32-104° F (0-40° C)
For indoor use only
Specifications subject to change without notice due to continuing product improvement
SPÉCIFICATIONS
ZW4009
Tension : 120VCA, 60Hz
Signal (fréquence) : 908.4/916MHz
Charges maximales : 960W incandescent, moteur de 1/2HP ou résistance de 1800W (15A)
Portée : Distance à vue entre la télécommande et le module de
réception Z-Wave le plus proche allant jusqu'à 150 pi (45.7m)
Plage de températures de fonctionnement : de 0 à 40°C (de 32 à 104°F)
Utilisation intérieure uniquement
En raison d'améliorations continues du produit, les spécifications
peuvent faire l'objet de changements sans préavis
ESPECIFICACIONES
ZW4009
Energía: 120VAC, 60Hz
Señal (frecuencia): 908.4/916MHz
Cargas máximas: 960W incandescente, 1/2HP motor o 1800W (15A) resistiva
Alcance: Hasta 150 pies (45.7m) en línea de visibilidad directa entre el
control inalámbrico y el módulo receptor Z-Wave más cercano
Rango de temperatura de funcionamiento: 0-40°C (32-104°F).
Para uso en espacios interiores solamente
Las especificaciones están sujetas a cambios sin previo aviso por
las constantes mejoras a que se someten los productos
Z-WAVE INTEROPERABILITY
This product can be included and operated in any Z-Wave network with
other Z-Wave certified devices from other manufacturers and/or other
applications. All non-battery operated nodes within the network will act as
repeaters regardless of vendor to increase reliability of the network.
INTEROPÉRABILITÉ ENTRE LES DISPOSITIFS Z-WAVE
Ce produit peut être utilisé dans un réseau Z-Wave avec d'autres appareils
certifiés Z-Wave produits par d'autres fabricants et d'autres applications. Tous les
nœuds fonctionnant sans pile au sein du réseau joueront le rôle de répétiteurs,
quel que soit le fournisseur, afin de rehausser la fiabilité du réseau.
INTEROPERABILIDAD Z-WAVE
Este producto se puede incluir y puede funcionar en cualquier red Z-Wave con dispositivos
de otros fabricantes y otras aplicaciones que cuenten con la certificación Z-Wave. Todos
los nodos que formen parte de la red y que funcionen sin pilas actuarán de repetidores
independientemente del proveedor con el fin de aumentar la fiabilidad de la red.
4
CONNECTION
CONNECTING YOUR DEVICE TO A Z-WAVE NETWORK
1.
Follow the instructions for your Z-Wave certified controller to add a
device to the Z-Wave network.
2.
Once the controller is ready to add your device, press up on the toggle.
A.
If prompted by the controller to enter the S2 security code, refer to
the QR code/security number on the back of the box, or the QR
code label on the product.
DSK :
XXXXX
-125651-22671
-26939-47599
-19612-25872
-47752
Now you have complete control to turn your fixture ON/OFF according to
groups, scenes, schedules and interactive automations programmed by your
controller. If your Z-Wave certified controller features remote access, you can
control your fixture from your mobile devices.
REMOVING AND RESETTING THE DEVICE
1.
Follow the instructions for your Z-Wave certified controller to remove a
device from the Z-Wave network.
2.
Once the controller is ready to remove your device, press up on the
toggle.
RETURNING SWITCH TO FACTORY DEFAULTS
Quickly press UP button 3 times, then, immediately press the DOWN button
3 times.
Note: This should only be used in the event your network's primary controller
is missing or otherwise inoperable.
This device supports Association Command Class (3 Groups)
• Association Group 1 supports Lifeline, Binary Switch Report
• Association Group 2 supports Basic Set and is controlled
by pressing the ON or OFF button with the local load
• Association Group 3 supports Basic Set and is controlled
by double pressing the ON or OFF button
• Each Association Group supports 5 total nodes

Advertisement

loading

Summary of Contents for Honeywell ZW4009

  • Page 1 If this switch is a The fixture controlled by the Honeywell In-Wall Smart Switch must not exceed 960W incandescent; 1800W (15A) resistive or 1/2HP motor. The switch is designed only for use with part of a 3-way or 4-way multi-switch installation, do not connect the traveler permanently installed fixtures.
  • Page 2 Honeywell estén instalados correctamente. Para forma permanente. obtener más información sobre instalaciones de 3 o 4 vías, consulte el manual o la guía rápida que viene con el interruptor auxiliar Honeywell. ¡IMPORTANTE! Antes de continuar, compruebe que se haya CARACTERÍSTICAS: INTERRUMPIDO la alimentación eléctrica a la caja del interruptor.
  • Page 3 39354/ZW4009 Parameter # Description Size (Byte) Default Valid Values 0 (default) - LED ON when device is OFF, LED OFF when device is ON 1 - LED ON when device is LED Indication Configuration ON, LED OFF when device is OFF...

This manual is also suitable for:

39354