Venting Methods

This range hood is factory set for venting through the roof or
through the wall. You can apply the recirculating venting method
by purchasing the Recirculation Kit.
The vent system needed for installation is not included.
A 6" (15.2 cm) round vent system is recommended.
Roof Venting
Wall Venting
A. 6" (15.2 cm) vent
A. 6" (15.2 cm) vent
through the roof
through the wall
B. Roof cap
B. Wall cap

Calculating Vent System Length

The recommended vent system is 6" (15.2 cm) round vent with a
maximum length of 35 ft (10.7 m). For the best performance, use
no more than three 90° elbows.
To calculate the length of the system, add the equivalent feet
(meters) for each of the vent pieces used in the system.
WARNING
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
IMPORTANT: The range hood must be electrically grounded in
accordance with local codes and ordinances, or in the absence
of local codes, with the National Electrical Code, ANSI/NFPA 70
(latest edition) or Canadian Electrical Code, CSA C22.1
No. 0-M91 (latest edition).
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate.
Recirculating
A. 6" (15.2 cm) vent
through the cabinet
B. Round recirculating grid

Electrical Requirements

Vent Piece
45° elbow
90° elbow
Example Vent System
90° elbow
2 ft (0.6 m)
Maximum Recommended Length
1 - 90° elbow
1 - wall cap
9 ft (2.8 m) straight
Length of 6" (15.2 cm) system
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
■ A 120 volt, 60 Hz, AC only, 15- or 20-amp, fused electrical
circuit is required. A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this range hood be provided.
■ This range hood is equipped with a power supply cord having
a 3 prong grounding plug.
■ To minimize possible shock hazard, the cord must be
plugged into a mating, 3 prong, grounding-type outlet,
grounded in accordance with local codes and ordinances. If a
mating outlet is not available, it is the personal responsibility
and obligation of the customer to have the properly grounded
outlet installed by a qualified electrician.
6
6" (15.2 cm)
2.5 ft
(0.8 m)
5.0 ft
(1.5 m)
Wall cap
6 ft (1.8 m)
= 35 ft (10.7 m)
= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 9.0 ft (2.8 m)
= 14.0 ft (4.3m)