Service - COMFORT-AIRE Century GDD95C Installation Instructions Manual

Warm air gas furnace downflow air discharge
Hide thumbs Also See for Century GDD95C:
Table of Contents

Advertisement

GDD95C110C5M Performance (Less Filter)
External
Bottom Return Air, Side Return Air with Optional Return Air Base, Return Air from Both Sides or Return Air from
Static
Bottom and One Side.
Pressure
High
in. w.c.
cfm
0.00
2285
0.10
2250
0.20
2185
0.30
2150
0.40
2085
0.50
2060
0.60
2005
0.70
1970
0.80
1910
NOTE: All air data is measured external to unit without filter (not furnished - field provided)
Model
045-3
070-4
090-4
110-5
Model
All Models
Factory Setting
Exhaust and Air Intake Pipe
1. Check exhaust and air intake connections for tightness
and to make sure there is no blockage.
2.
Is pressure switch closed? Obstructed exhaust pipe
will cause unit to shut off at pressure switch. Check
termination for blockages.
3.
Obstructed pipe or termination may cause rollout
switches to open. Reset manual flame rollout switches
on burner box assembly if necessary.

Service

At the beginning of each heating season, system should
be checked as follows by a qualified service technician:
Page 44 of 53
Air Volume / Watts at Different Blower Speeds
Medium-High
watts
cfm
watts
640
1990
435
660
1965
450
675
1910
465
690
1850
485
710
1810
495
725
1765
515
745
1700
535
760
1665
550
775
1620
560
Allowable Heating Speeds
Red
Yellow
Not Allowed
Allowed
Not Allowed
Allowed
Allowed
Allowed
Not Allowed
Allowed
Allowable Circulation Speeds
Red
Yellow
Not Allowed
Medium
cfm
watts
1805
330
1775
345
1720
360
1670
375
1605
395
1565
400
1510
420
1460
440
1420
450
Blue
Factory Setting
Allowed
Allowed
Allowed
Table 16.
Blue
Not Allowed
Table 17.
ELECTRICAL SHOCK, FIRE, OR EXPLOSION
Failure to follow safety warnings exactly could result in
dangerous operation, serious injury, death or property
damage.
Improper servicing could result in dangerous operation,
serious injury, death, or property damage.
Before servicing, disconnect all electrical power to
furnace.
When servicing controls, label all wires prior to
disconnecting. Take care to reconnect wires correctly.
Verify proper operation after servicing.
Issue 1933
Medium-Low
cfm
watts
cfm
1685
265
1480
1630
280
1430
1575
295
1360
1525
310
1290
1465
325
1255
1420
335
1190
1370
355
1160
1325
370
1100
1275
380
1045
Brown
Not Allowed
Factory Setting
Factory Setting
Factory Setting
Brown
Not Allowed
WARNING
HAZARD.
Low
watts
195
205
215
235
245
255
270
280
295
Black
Not Allowed
Not Allowed
Not Allowed
Not Allowed
Black
Not Allowed
507735-03

Advertisement

Table of Contents
loading

Table of Contents