Vermont Castings DVT38IN Installation Instructions And Homeowner's Manual page 40

Direct vent gas fireplace
Hide thumbs Also See for DVT38IN:
Table of Contents

Advertisement

Chateau™
Kit #
Model
20011992
DVT38IP
20012367
DVT44IP
Table 2 Air Shutter Settings
Model
Air Shutter Setting
DVT38IP
DVT44IP
2
Table 3 Valve Minimum Rate Screw
Model
DVT38IP
#31 (.120")
DVT44IP
No Shank Screw
40
Table 1 Injector Orifice Size Matrix
Conversion to LP
Front
Part #
Middle
#66
20009182
(.033")
(.041")
#63
20006251
(.037")
(.043")
Conversion to LP
Burner Tube
Burner Housing
Air Shutter Setting
Fully open
Fully open
Size
Part #
20012364
20012264
Burner Orifice
Part #
Rear
#59
20000664
#50
(.070")
#57
20004587
#49
(.073")
n/a
Fully open
Pilot Flame Adjustment
Typically, the top 3/8" or 1/2" of the pilot flame sensor
should be engulfed in the pilot flame. (Page 28, Fig. 50)
To adjust pilot burner:
1. Locate pilot adjustment screw on the valve next to
the black plastic cap. Refer to Page 30.
2. Adjust pilot screw to provide proper sized flame.
Only a small adjustment should be needed.
NOTE: Do not rotate screw excessively. Do not adjust
any other screws on the valve.
Input (BTU/hr)
Part #
Minimum Maximum
30000337
34,000
20006252
45,000
46,000
60,000
20011956