Congratulations on purchasing your new Lancaster Water Softener. This unit is designed to give
you many years of trouble free service. When installed in accordance with the following instructions
and if given reasonable care, clear-soft water will be the result. For servicing and future inspection
purposes, please file this booklet with your important documents.
INSTALLATION, OPERATING
AND SERVICE MANUAL
GOLD LINE LER
WITH THE LERCV1 VALVE
PAGE 1

Advertisement

Table of Contents
loading

Summary of Contents for Lancaster Water Treatment X FACTOR GOLD LINE LER

  • Page 1 INSTALLATION, OPERATING AND SERVICE MANUAL GOLD LINE LER ELECTRONIC WATER SOFTENER WITH THE LERCV1 VALVE 7-LECR-50B 7-LECR-75B 7-LECR-100B 7-LER-75B 7-LER-100B 7-LER-150B 7-LER-200B Congratulations on purchasing your new Lancaster Water Softener. This unit is designed to give you many years of trouble free service. When installed in accordance with the following instructions and if given reasonable care, clear-soft water will be the result.
  • Page 2: Operating Parameters

    OPERATING PARAMETERS Minimum / Maximum Operating Pressures 20 psi (138 kPa) - 125 psi (862 kPa) Minimum / Maximum Operating Temperatures 40°F (4°C) - 110°F (43°C) Supply Voltage/ Frequency 120V AC/ 60 Hz Other Options Available Power Consumption 9.5 W Output Voltage 12V AC Output Current...
  • Page 3: Installation

    The control valve uses no traditional fasteners (e.g. screws); instead clips, threaded caps and nuts and snap type latches are used. Caps and nuts only need to be firmly hand tightened because radial seals are used. Tools required to service the valve include one small blade screw driver, one large blade screw driver, pliers and a pair of hands.
  • Page 4 TO INSTALL 5/8” POLY TUBE DRAIN LINE: The poly tube insert is shipped attached to the drain line elbow’s locking clip. Press the insert into the drain line (5/8” poly tube not included). Loosen nut of the drain line elbow. Press 5/8” poly tube with insert into the drain line elbow until it seats on the back of the fitting.
  • Page 5: Set Time Of Day

    SET TIME OF DAY Current time of day needs to be entered during initial installation, and adjusted when daylight saving time begins or ends. If an extended power outage occurs and depletes the on-board non-rechargeable coin cell battery, when power resumes the time of day should be reset and battery replaced.
  • Page 6 STEP 5 – Next Regeneration Time (minutes): Set the minutes of day for regeneration using STEP 5 buttons. Press to return to normal operation. Press to return to NEXT REGEN previous step. RETURN TO NORMAL MODE PLACING UNIT INTO SERVICE: Make sure inlet and outlet valves are to their closed positions. If using optional bypass, place in bypass position.
  • Page 7 OPTIONAL MAINTENANCE WRENCH Part Number V3193 Although no tools are necessary to assemble the valve, the optional maintenance wrench (shown in various positions on the valve) may be purchased to aid in assembly or disassembly. Loosens Drain Nut In Polytube Applications Loosens Injector And Bypass Caps Loosens Quick...
  • Page 8: Drive Assembly

    SERVICE INSTRUCTIONS DRIVE ASSEMBLY: The drive assembly consists of the following parts: • Drive Bracket • Printed Circuit (PC) Board • Motor • Drive Gears • Drive Gear Cover The drive bracket holds the PC board, the motor, the drive gears and the drive gear cover in place. The PC board receives and retains information, displays the information, determines when to regenerate and initiates regeneration.
  • Page 9: Drive Cap Assembly, Main Piston And Regenerant Piston

    Replace broken or damaged drive gears. Do not lubricate any of the gears. Avoid getting any foreign matter on the reflective coating because dirt or oils may interfere with pulse counting. The drive gear cover only fits on one way, with the large clip orientated towards the bottom. If all three clips are outside of the gear shroud on the drive bracket the drive gear cover slips easily into place.
  • Page 10: Injector Cap, Screen, Injector Plug And Injector

    INJECTOR CAP, SCREEN, INJECTOR PLUG AND INJECTOR: The screen, injector and/or injector plug(s) are installed under the injector cap in an easy to access location on top of the valve. The injector cap contains four slots so no water accumulates in the cap. The injector cap is designed to be hand tightened.
  • Page 11: Front Cover And Drive Assembly

    Supply Frequency 60 Hz Battery Fully Seated Output Voltage 12 V AC Output Current 500 mA When replacing the battery, align Correct WS1TC & WS1.25 TC Manual Page 13 FRONT COVER AND DRIVE ASSEMBLY positives and push down to fully seat. Battery Battery replacement is Orientation...
  • Page 12: Water Meter And Meter Plug

    WATER METER AND METER PLUG WS1 & WS1.25 Drawings & Service Manual Item No. Quantity Part No. Description Drain Line – 3/4” Drawing No. Order No. Description Quantity V3151 Nut 1” QC H4615 Elbow Locking Clip PKP10TS8-BULK Polytube insert 5/8 Option V3192 V3003*...
  • Page 13 PARTS        V3007 1” PVC Male NPT Elbow Assembly  Standard Item No. Part No. Description  V3151 Nut 1” Quick Connect   V3150 Split Ring  V3105 O-Ring 215   V3149 1”...
  • Page 14: Troubleshooting Procedures

    TROUBLESHOOTING PROCEDURES PROBLEM POSSIBLE CAUSE SOLUTION a. Transformer unplugged a. Connect power 1. Timer does not display time of b. No electric power at outlet b. Repair outlet or use working outlet day. c. Defective transformer c. Replace transformer d. Defective PC board d.