Emerson Dixell XR70CX Installing And Operating Instructions page 5

Digital controller with defrost and fan management

Advertisement

Label
Name
Con Compressor ON time with faulty probe
CoF Compressor OFF time with faulty probe
CF Temperature measurement unit
rES Resolution
Lod Probe displayed
rEd
X-REP display
2
dLY Display temperature delay
dtr P1-P2 percentage for display
tdF Defrost type
dFP Probe selection for defrost termination
dtE Defrost termination temperature
idF Interval between defrost cycles
MdF (Maximum) length for defrost
dSd Start defrost delay
dFd Displaying during defrost
dAd MAX display delay after defrost
Fdt Draining time
dPo First defrost after start-up
dAF Defrost delay after fast freezing
FnC Fan operating mode
Fnd Fan delay after defrost
Differential of temperature for forced
FCt
activation of fans
FSt Fan stop temperature
Fon Fan on time with compressor off
FoF Fan off time with compressor off
FAP Probe selection for fan management
ALC Temperat. alarms configuration
ALU MAXIMUM temperature alarm
ALL Minimum temperature alarm
AFH Differential for temperat. alarm recovery
ALd Temperature alarm delay
dAo Delay of temperature alarm at start up
AP2 Probe for temperat. alarm of condenser
AL2 Condenser for low temperat. alarm
AU2 Condenser for high temperat. alarm
Differ. for condenser temp. alar.
AH2
recovery
Ad2 Condenser temperature alarm delay
dA2 Delay of cond. temper. alarm at start up
Compr. off for condenser low
bLL
temperature alarm
Compr. off for condenser high
AC2
temperature alarm
tbA Alarm relay disabling
oA3 Fourth relay configuration
AoP Alarm relay polarity (oA3=ALr)
i1P Digital input polarity (18-19)
i1F Digital input configuration (18-19)
did Digital input alarm delay (18-20)
nPS Number of activation of pressure switch
Compress and fan status when open
odC
door
rrd Regulation restart with door open alarm
HES Differential for Energy Saving
Adr Serial address
PbC Kind of probe
onF on/off key enabling
dP1 Room probe display
dP2 Evaporator probe display
dP3 Third probe display
dP4 Fourth probe display
rSE Real set
rEL Software release
Ptb Map code
1592020070 XR70CX GB m&M r1.3 27.03.2015
Range
Value Level
0 to 255 min
15
0 to 255 min
30
°C; °F
°C
dE; in
dE
P1; P2; P3; P4; SEt; dtr
P1
P1; P2; P3; P4; SEt; dtr
P1
0.0 to 20min00sec, res. 10 sec
0.0
1 to 99
50
EL; in
EL
nP; P1; P2; P3; P4
P2
[-55 to 50.0°C]
8
[-67 to 122°F]
0 to 120 hours
6
0 to 255 min
30
0 to 255 min
0
rt; it; SEt; dEF
it
0 to 255 min
30
0 to 255 min
0
n; Y
n
0.0 to 24h00min, res. 10 min
0.0
C-n; o-n; C-Y; o-Y
o-n
0 to 255 min
10
[0 to 50°C]
10
[0 to 90°F]
[-55 to 50.0°C]
2
[-67 to 122°F]
0 to 15 min
0
0 to 15 min
0
nP; P1; P2; P3; P4
P2
rE; Ab
Ab
Rel: [0.0 to 50.0°C] [0 to 90°F]
110.0
AbS: [ALL to 150°C] [ALL to 302°F]
Rel: [0.0 to 50.0°C] [0 to 90°F]
AbS: [-100°C to ALU] [-148°F to
-50.0
ALU]
[0.1 to 25.5°C]
1.0
[1 to 45°F]
0 to 255 min
15
0.0 to 24h00min, res. 10 min
1.3
nP; P1; P2; P3; P4
P4
[-100 to 150°C]
-40
[-148 to 302°F]
[-100 to 150°C]
110
[-148 to 302°F]
[0.1 to 25.5°C]
5
[1 to 45°F]
0 to 254 min, 255(nu)
15
0.0 to 24h00min, res. 10 min
1.3
n; Y
n
n; Y
n
n; Y
Y
ALr = alarm; dEF = do not select it;
LiG =Light; AUS =AUX; onF=always
on; FAn= do not select it; db = neutral
ALr
zone; CP2 = second compressor;
dF2 = do not select it
oP; CL
CL
oP; CL
CL
EAL; bAL; PAL; dor; dEF; ES; AUS;
dor
Htr; FAn; HdF; onF
0 to 255 min
15
0 to 15
15
no; FAn; CPr; F-C
F-C
n; Y
Y
[-30 to 30°C]
0
[-54 to 54°F]
0 to 247
1
PtC; ntC
ntC
nu; oFF; ES
nu
probe value
-
probe value
-
probe value
-
probe value
-
actual set
-
read only
-
read only
-
Pr2
Pr2
Pr2
Pr1
Pr2
Pr2
Pr2
Pr2
Pr1
Pr2
Pr1
Pr1
Pr1
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr1
Pr1
Pr2
Pr1
Pr2
Pr2
Pr2
Pr2
Pr1
Pr1
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr1
Pr1
Pr1
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr1
Pr1
Pr1
Pr1
Pr2
Pr2
Pr2
XR70CX
5/5