Hoshizaki SRK-8H Instruction Manual
Hoshizaki SRK-8H Instruction Manual

Hoshizaki SRK-8H Instruction Manual

Modular crescent cuber
Hide thumbs Also See for SRK-8H:

Advertisement

Quick Links

Hoshizaki
Hoshizaki America, Inc.
"A Superior Degree
of Reliability"
www.hoshizaki.com
Modular Crescent Cuber
Serenity Series
Model
KMS-830MLH
Including
Condensing Unit Models
SRK-8H/3
INSTRUCTION MANUAL
Issued: 4-28-2015

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SRK-8H and is the answer not in the manual?

Questions and answers

Summary of Contents for Hoshizaki SRK-8H

  • Page 1 Hoshizaki Hoshizaki America, Inc. Modular Crescent Cuber Serenity Series Model KMS-830MLH Including Condensing Unit Models SRK-8H/3 INSTRUCTION MANUAL “A Superior Degree of Reliability” www.hoshizaki.com Issued: 4-28-2015...
  • Page 2 Should the reader have any questions or concerns which have not been satisfactorily addressed, please call, send an e-mail message, or write to the Hoshizaki Technical Support Department for assistance. Phone: 1-800-233-1940; (770) 487-2331 Fax: 1-800-843-1056;...
  • Page 3: Table Of Contents

    A. Electrical and Refrigerant Data ..................6 1. KMS-830MLH......................6 2. SRK-8/3H ........................ 6 B. Dimensions/Connections ....................7 1. KMS-830MLH......................7 2. SRK-8H/3 ........................ 8 II. Installation and Operating Instructions ................9 A. Location ........................9 B. Checks Before Installation ....................11 1. Icemaker .........................11 2.
  • Page 4: Important Safety Information

    Important Safety Information Throughout this manual, notices appear to bring your attention to situations which could result in death, serious injury, damage to the appliance, or damage to property. WARNING Indicates a hazardous situation which could result in death or serious injury.
  • Page 5 WARNING, continued Icemaker • Do not connect the icemaker to an external power source. Icemaker power supply and ground connection are supplied from the remote condensing unit via the wire bundle provided with the remote condensing unit. • Wire bundle routing (conduit) and disconnect (if required) must meet national, state, and local electrical code requirements.
  • Page 6: Specifications

    115V 0.8A Design Pressure HI-467PSI LO-230PSI Total Refrigerant 404A Charge Total Refrigerant Charge with Hoshizaki Remote Condensing Unit SRK-8H/3: 13 LB. 9 OZ. 2. SRK-8/3H Model Number SRK-8H SRK-8H3 AC Supply Voltage 208-230/60/1 (3 wire with neutral 208-230/60/3 for 115V) Compressor 208-230V 7.7RLA 56LRA...
  • Page 7: Dimensions/Connections

    B. Dimensions/Connections 1. KMS-830MLH...
  • Page 8: Srk-8H/3

    2. SRK-8H/3...
  • Page 9: Installation And Operating Instructions

    II. Installation and Operating Instructions WARNING • The icemaker and remote condensing unit must be installed in accordance with applicable national, state, and local codes and regulations. • Failure to install, operate, and maintain the appliance in accordance with this manual will adversely affect safety, performance, component life, and warranty coverage and may result in costly water damage.
  • Page 10 2. Remote Condensing Unit NOTICE • The remote condensing unit is intended for outdoor use. Normal operating ambient temperature must be within -20°F to 122°F (-29°C to 50°C). Operation of the remote condensing unit, for extended periods, outside of this normal temperature range may affect performance.
  • Page 11: Checks Before Installation

    • This icemaker can be installed on a dispenser unit or ice storage bin 30" wide or wider. For options, contact your local Hoshizaki distributor. • NOTICE! This icemaker is designed for connection to Hoshizaki Remote Condensing Unit Model SRK-8H or SRK-8H3 only! Connection to another remote condensing unit will void the warranty. 2. Remote Condensing Unit •...
  • Page 12: How To Remove Panels

    C. How to Remove Panels 1. Icemaker • Front Panel: Remove the screw. Lift up and towards you. • Control Box Cover: Remove the screw and pull towards you. • Top Panel: Lift off. • Top Insulation Panel: Lift off. •...
  • Page 13: Setup

    2) Position the dispenser unit/ice storage bin in its permanent location. 3) If required, install an adapter kit or top kit. Contact your local Hoshizaki distributor for recommendations. 4) Level the dispenser unit/ice storage bin in both the left-to-right and front-to-rear directions.
  • Page 14: Bin Control Installation

    2. Bin Control Installation NOTICE Before operating the icemaker, the bin control must be installed. Failure to properly install the bin control could result in ice backup and icemaker damage. Follow the instructions below for bin control assembly installation. 1) Remove the front panel. 2) Remove the bin control insulation and bin control cover.
  • Page 15: Installation Of The Remote Condensing Unit

    The "S" oil-trap must be located halfway between the icemaker and remote condensing unit. This ensures sufficient oil return to the compressor. Line Set Size and Length for SRK-8H/3 Remote Condensing Units Hoshizaki Liquid...
  • Page 16: Line Set Installation

    3. Line Set Installation WARNING • R-404A itself is not flammable at atmospheric pressure and temperatures up to 176°F (80°C). • R-404A itself is not explosive or poisonous. However, when exposed to high temperatures (open flames), R-404A can be decomposed to form hydrofluoric acid and carbonyl fluoride both of which are hazardous.
  • Page 17 13) Insulate all exposed tubing and fittings. Hoshizaki Technical Support is available at 1-800-233-1940 for recommendations Line Set Connections Icemaker Remote Condensing Unit (with compressor) Storage Max. 16.5 Feet Max. Suction Line Max. "S" Oil-Trap Feet Feet Max. Service Loop 16.5...
  • Page 18: Electrical Connection

    F. Electrical Connection WARNING Icemaker • Do not connect the icemaker to an external power source. Icemaker power supply and ground connection are supplied from the remote condensing unit via the wire bundle provided with the remote condensing unit. • Wire bundle routing (conduit) and disconnect (if required) must meet national, state, and local electrical code requirements.
  • Page 19 4) Replace all removed parts and panels in their correct positions. 5) Turn on the power supply to the remote condensing unit. NOTICE! The remote condensing unit must have power for a minimum of 4 hours prior to startup to prevent compressor damage. SRK-8H SRK-8H3  WARNING  WARNING...
  • Page 21: Water Supply And Drain Connections

    • A plumbing permit and services of a licensed plumber may be required in some areas. • External filters, strainers, or softeners may be required depending on water quality. Contact your local Hoshizaki distributor for recommendations. • Water supply pressure must be a minimum of 10 PSIG and a maximum of 113 PSIG. If the pressure exceeds 113 PSIG, the use of a pressure reducing valve is required.
  • Page 22 1. Icemaker Icemaker Water Minimum Icemaker Icemaker Drain Minimum Icemaker Supply Inlet Water Supply Line Size Outlet Drain Line Size 1/2" Female Pipe 1/4" Nominal ID 3/4" Female Pipe 3/4" Nominal Thread (FPT) Copper Water Tubing or Thread (FPT) ID Hard Pipe or Equivalent Equivalent •...
  • Page 23: Final Checklist

    H. Final Checklist WARNING CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation. Make sure that none have fallen into the dispenser unit/ice storage bin. 1) Is the icemaker level? 2) Is the icemaker in a site where the ambient temperature is within 45°F to 100°F (7°C to 38°C) and the water temperature within 45°F to 90°F (7°C to 32°C) all year around? 3) Is there at least 6"...
  • Page 24: Startup

    I. Startup WARNING All parts are factory-adjusted. Improper adjustments may adversely affect safety, performance, component life, and warranty coverage. NOTICE • If the appliance is turned off, wait for at least 3 minutes before restarting the appliance to prevent damage to the compressor. •...
  • Page 25 9) Remove the overflow cap and overflow pipe. 10) Remove the drain plug. Allow the water tank to drain, then replace the drain plug in its correct position. Be careful not to cross thread it. 11) Replace the overflow pipe, overflow cap, cube guide A, and cube guide B in their correct positions.
  • Page 26: Maintenance

    III. Maintenance The appliance must be maintained in accordance with the instruction manual and labels provided. Consult with your local Hoshizaki Certified Service Representative about maintenance service. WARNING • Only qualified service technicians should service the appliance. • To reduce the risk of electric shock, do not touch the control switch with damp hands.
  • Page 27: Cleaning And Sanitizing Instructions

    B. Cleaning and Sanitizing Instructions The icemaker must be cleaned and sanitized at least once a year. More frequent cleaning and sanitizing may be required in some water conditions. WARNING • To prevent injury to individuals and damage to the icemaker, do not use ammonia type cleaners.
  • Page 28 7) Remove the top, left side, and insulation panels, then pour 14 fl. oz. (414 ml) of Hoshizaki "Scale Away" into the water tank. Replace the insulation, left side, and top panels. Turn the cleaning valve to the left until completely vertical (open).
  • Page 29 12) In bad or severe water conditions, turn off the power supply, then remove, clean (cleaning solution = 5 oz. Hoshizaki "Scale Away" per gallon of warm water), rinse, and replace the cube guides, float switch, water supply tubes, spray tubes, and spray guides;...
  • Page 30 22) Remove the overflow cap, overflow pipe, and drain plug. After the water tank has drained, replace the drain plug, overflow pipe, overflow cap, cube guide A, cube guide B, and reconnect the distributor to the distribution hose, then replace the insulation, left side, and top panels.
  • Page 31 34) Remove the overflow cap, overflow pipe, and drain plug. After the water tank has drained, replace the drain plug, overflow pipe, overflow cap, cube guide A, and cube guide B, and reconnect the distributor to the distribution hose, then replace the insulation, left side, and top panels 35) Clean the dispenser unit/ice storage bin liner using a neutral cleaner.
  • Page 32: Preparing The Icemaker For Periods Of Non-Use

    IV. Preparing the Icemaker for Periods of Non-Use NOTICE • When storing the icemaker for an extended time or in sub-freezing temperatures, follow the instructions below to prevent damage. • To prevent damage to the water pump seal, do not leave the control switch in the "WASH"...
  • Page 33: Disposal

    V. Disposal The appliance contains refrigerant and must be disposed of in accordance with applicable national, state, and local codes and regulations. Refrigerant must be recovered by properly certified service personnel.
  • Page 34 HOSHIZAKI AMERICA, INC. 618 Hwy. 74 S., Peachtree City, GA 30269 USA TEL (770) 487-2331 FAX (770) 487-3360 www.hoshizaki.com 1A3757-010...

This manual is also suitable for:

Kms830mlhSrk-8h3

Table of Contents