Installation; Recommended Tools And Accessories For Installation; Install Ductwork (Ducted Installations Only) - Broan NPLEC1 Installation Use And Care Manual

Table of Contents

Advertisement

For ADA compliance installation guidelines, please type the model number into our website.
Recommended Tools and Accessories
for Installation
Measuring tape
Phillips screwdriver no. 2
Nut driver or socket 11/32"
Flat blade screwdriver (to open knockout holes)
Drill, 1/8" drill bit and 1½" hole saw (to mark holes for ducting and cut electrical access hole)
7/64" drill bit (to drill holes for EZ1 brackets mounting screws)
7" round duct plate, not included in NPLEC1 Series (for 7'' round vertical ducting installation,
part no.: SR680508)
Wood shims (2) and wood screws (4) (required for standard installation to framed cabinet)
Saw (to cut holes for ducted application)
Sheet metal shears (ducted installation only, for duct adjustment)
Pliers (ducted installation only, for duct adjustment)
Metal foil duct tape (for ducted applications)
Scissors (to cut metal foil duct tape)
Pencil
Wire stripper
Strain relief, 1/2" diameter (to secure house wiring cable to the hood)

Install Ductwork (Ducted Installations Only)

24"
ABOVE COOKING SURFACE
NOTE: Distances over 30" are at the installer and user discretion.
1 ] Determine whether hood will discharge vertically (3¼" x 10" , 3¼" x 14" or 7" round),
or horizontally (3¼" x 10" or 3¼" x 14" only).
2 ] Decide where the ductwork will run between the hood and the outdoors.
3 ] The ducting from this fan to the outside of the building has a strong effect on the air flow,
noise and energy use of the fan. Use the shortest, straightest duct routing possible for best
performance, and avoid installing the fan with smaller ducts than recommended. Insulation
around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing
ducts may not achieve their rated airflow. Refer to the table on next page to help you plan the
most efficient installation..
NOTE: To use 6" round ducting, install a 3¼" x 10" to 6" round transition (not included). The
performances may be affected.
4 ] Install wall cap or roof cap (sold separately); ensure there is no leak in house insulation.
Connect metal ductwork to cap and work back towards the hood location. Use 2" metal foil
duct tape to seal the joints between ductwork sections.
R
OOF CAP
S
OFFIT
C
ABINET
H
OOD
- 30"
MIN
MAX
3¼"
10", 3¼"
14"
X
X
OR
7"
ROUND DUCT
(F
OR VERTICAL
)
DISCHARGE
H
OUSE WIRING
(T
)
OP OR BACK OF HOOD
W
ALL CAP
3¼"
10"
X
OR
3¼"
14"
X
DUCT
(F
)
OR HORIZONTAL DISCHARGE
7