Superior Fireplaces VRT4032ZEP Manual page 4

Unvented (vent-free) radiant and louvered faced fireplace system with logs and thermostat blower
Table of Contents

Advertisement

1. WARNING: This appliance is only for
use with the type of gas indicated on
the rating plate. This appliance is not
convertible for use with other gases.
2. Do not place propane/LP supply tank(s)
inside any structure. Locate propane/
LP supply tank(s) outdoors (propane/LP
only).
3. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not
use any phone in your building
• immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions
• if you cannot reach your gas supplier,
call the fi re department
4. This fi replace shall not be installed in a
bedroom or bathroom.
5. Do not use this fi replace as a wood-burn-
ing fi replace. Use only the logs provided
with the fi replace.
6. Do not add extra logs or ornaments such
as pine cones, vermiculite, or glowing
embers. Using these added items can
cause sooting. Do not add volcanic stone
around base. Volcanic Stone and debris
could fall into the control area of fi replace.
7. This fi replace is designed to be smoke-
less. If logs ever appear to smoke, turn
off fi replace and call a qualifi ed service
person.
NOTE: During initial operation, slight
smoking could occur due to log curing and
fi replace burning manufacturing residues.
8. To prevent the creation of soot, follow the
instructions in Cleaning and Maintenance,
Page 24.
9. Before using furniture polish, wax, carpet
cleaner, or similar products, turn heater
4
SAFETY
Continued
off. If heated, the vapors from these prod-
ucts may create a white powder residue
within burner box or on adjacent walls or
furniture.
10. This fi replace needs fresh air ventilation
to run properly. This fireplace has an
Oxygen Depletion Sensing (ODS) safety
shutoff system. The ODS shuts down the
fi replace if not enough fresh air is avail-
able.
See Air for Combustion and Ventilation,
Page 7. If fi replace keeps shutting off, see
Troubleshooting, Page 25.
11. Do not run fi replace
• where fl ammable liquids or vapors are
used or stored.
• under dusty conditions.
12. Do not use this fi replace to cook food or
burn paper or other objects.
13. Never place any objects in the fi replace
or on logs.
14. Do not use fi replace if any part has been
under water. Immediately call a qualifi ed
service technician to inspect the room
fi replace and to replace any part of the
control system and any gas control which
has been under water.
15. Turn off and unplug fireplace and let
cool before servicing. Only a qualifi ed
service person should service and repair
fi replace.
16. Operating fi replace above elevations of
4,500 feet could cause pilot outage.
17. Do not operate fireplace if any log is
broken. Do not operate fi replace if a log
is chipped (dime-sized or larger).
18. To prevent performance problems, do not
use propane/LP fuel tank of less than 100
lbs. capacity (propane/LP only).
19. Provide adequate clearances around air
openings.
20. The screen or any other part removed
for servicing must be replaced prior to
operating this heater.
SuperiorFireplaces.us.com