Connecting Cables Between Indoor Unit And Outdoor Unit - LG ATUQ18GQSK1 Installation Manual

Table of Contents

Advertisement

WIRING CONNECTION
10

Connecting cables between indoor unit and outdoor unit

Outdoor
unit
3
2
1
!
CAUTION
The power cord connected to the outdoor unit should be complied with IEC 60245 or HD 22.4
S4 (This equipment shall be provided with a cord set complying with the national regulation.
10±3 mm
The connecting cable connected to the outdoor unit should be complied with IEC 60245 or
HD 22.4 S4 (This equipment shall be provided with a cord set complying with the national
regulation.)
10±3 mm
If the supply cord is damaged, it must be replaced by a special cord or assembly availible
from the manufacturer of its service agent.
Indoor
unit
3
2
1
When the connection line between the indoor unit and out-
dooor unit is over 40 m, connect the telecommunication line
and power line separately.
NORMAL
CROSS-SECTIONAL
AREA 0.75 mm
2
Model
ATUQ18GQSK1
ATUQ24GQSK1
APUQ18GS1K1
APUQ30GS1K1
ATUQ18GQSK1
ATUQ24GQSK1
1
APUQ18GS1K1
APUQ30GS1K1
Phase(Ø) Area(mm
1
2.5
0.75
2
)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Apuq30gs1k1Atuq24gqsk1Apuq18gs1k1

Table of Contents