2. Opti-Serve Model
CB K8 connector pins #7 (R), #8 (P), and #9 (BK): Before engaging the water
dispense OS sensor, check for the correct VDC from the locations given in the
"Disengaged" column in the table below. If the VDC is different than in the table,
replace CB. If the VDC is correct, engage the OS sensor. "WTRDP" LED turns on.
If not, confirm that the water dispense signal VDC matches the "Engaged" column
in the table below. If not, replace the OS sensor. If the VDC matches the "Engaged"
column below and the "WTRDP" LED does not turn on, replace CB.
Component
VDC Sensor Ground
Water Dispense Signal
5VDC Power Supply
Red test lead
to CB red
K4 pin #1 (pin
closest to CB
black K3)
5VDC CB K7 Connector
Pin # (Wire Color)
#7 (R)
#8 (P)
#9 (BK)
Multimeter
5VDC
Red Test Lead
Water Dispense (BK)
(5VDC power)
Water Dispense (P)
(switch signal)
To CB VDC Ground
Red K4 pin #1
To
(closest to CB
black K3)
Black Test Lead
Water Dispense (R)
(VDC GND)
Fig. 4
19
Disengaged Engaged
0VDC
0VDC
0VDC
5VDC
5VDC
5VDC
Control Board K7 Connector