Group Control; Two Thermistor System - LG LBUH366GSS0 Installation Manual

Concealed duct
Table of Contents

Advertisement

Group Control

Group Control
It operates maximum 16 Units by only one Wired Remote Controller,
and each Unit starts sequentially to prevent overcurrent.
Terminal(Local Supply)
Block
RED(12V)
YL(SIGNAL)
BR(GND)
AUTO SWING
OPERATION
SET TEMP
FAN SPEED
SUB FUNCTION
Room Temp
HI
AUTO
Heater
Preheat
MED
JET
Defrost
Humidify
LO
Filter
Out door
Time
ZONE
1 2 3 4
Timer
Operation unit
Program set
On
Off
Set no. Time
01
03
05
07
09
11
13
15
17
19
21
23
Slide Switch2

Two Thermistor system

• Open the rear cover of Remote Controller to
set up the mode.
• Selectable options are three as follows.
- Remo: Sensing the room Temperature.
- Indoor Unit: Sensing the intake air into
indoor Unit.
- 2 TH: Sensing the lower temperature of the
two thermistors.
• To set up the mode, adjust the slide switch to
desired mode position on installing.
28 Concealed Duct Air Conditioner
Indoor Unit 1
Terminal(Local Supply)
Block
Connector
RED(12V)
Main PCB
YL(SIGNAL)
YL(SIGNAL)
#1
BR(GND)
BR(GND)
Wired Remote Controller
(Standard)
Single
Group
Remote
Controller
PCB
Main PCB
Indoor Unit 2
Connector
Main PCB
YL(SIGNAL)
....
YL(SIGNAL)
#2
BR(GND)
BR(GND)
Connecting Cable(Local Supply)
....
• Using the supplied Wired Remote Controller,
wire them like above.
• Move slide switch 2 to "Group" position.
• Ensure that the color of wire.
Slide Switch1
Slide Switch2
Indoor Unit 16
Terminal(Local Supply)
Block
Connector
Main PCB
YL(SIGNAL)
#16
BR(GND)
Room Temp. Sensing
Remo.
Indoor Unit
2 TH(Remo.+Indoor)
Single
Group
CAUTION
• On installing, don't impact to the PCB
and LCD display.
• Don't remove the protection sheet.
• Use the specified screw.
• On installing, turn off the main power.