13. OPERATING PROCEDURES

13.3 BY COUNT OPERATION

The BY-COUNT mode is used to issue the label of commodities of the same kind in a package (or may
not be packed). The whole package quantity (or a certain quantity) and the whole package price (or
the price per the quantity) are usually preset. Thus, it is not necessary to weigh the commodities by
the scale in such cases.
Menu: REG., M.DOWN, or REWRAP
Mode: BY-COUNT
Example) In case of sell 10 DONUTS at the price of $1.50 per 4 DONUTS. (When a price of $1.50/4
DONUTS is set for PLU #33.)
Enter the quantity of
purchase
(Max. 2 digits)
The label is issued in
succession after peeling it.
Press to suspend label
issue temporarily.
Press to cancel label
issue.
The display returns to the
initial screen.
3
Enter the PLU #.
PLU
1
PRT
AUTO
Press to
PRT
resume
C
*
label issue.
C
PLU
(Sample label for US type)
US type
3
<REG.> MANU.
DONUTS
CA/QR type
0
<REG.> MANU.
DONUTS
*
MANUAL
Single label is issued.
TEC STORE
(TEL) 0123-45-6789
13- 4
13.3 BY COUNT OPERATION
BY-COUNT
PCS
UNIT/$
10
4/1.50
BY-COUNT
Kg
$/Kg
----
P
10
TEC STORE
(TEL) 0123-45-6789
(Sample label for CA and QR types)
TOTAL $
3.76
$
3.76