Technical specifications

Technical specifications
Type
Indoor unit

Information about refrigerant

Important information: regulation regarding the refrigerant used

This product contains fluorinated greenhouse gases. Do not vent gases into the atmosphere.
CAUTION
• If the system contains 5 tCO
for leakage at least once every 12 months, according to regulation No. 517/2014. This activity
must be covered by qualified personnel only. In the case of the situation above, the installer (or
authorized person with responsibility for final check) must provide a maintenance book, with
all the information recorded, according to REGULATION (EU) No. 517/2014 OF THE EUROPEAN
PARLIAMENT AND OF THE COUNCIL of 16 April 2014 on fluorinated greenhouse gases.
This indoor unit can be connected to an R-32 or R-410A outdoor unit.
 R-32: Single / DPM
 R-410A: DPM only (available with AC200/250KXAPNH)
Refrigenat type
R-32
R-410A
• GWP: Global Warming Potential
• Calculating tCO
e: kg x GWP/1000
2
20
English
Model
AC026RNNDKG
AC035RNNDKG
AC052RNNDKG
AC071RNNDKG
e or more of fluorinated greenhouse gases, it must be checked
2
GWP value
675
2088
Net weight (kg)
Net dimension (W x D X H) (mm)
11.5
11.5
12.0
12.0
575 x 575 x 250
575 x 575 x 250
575 x 575 x 250
575 x 575 x 250