Chassis no. ms-b

Advertisement

SERVICE
ADJUSTMENT ITEM
NUMBER
D07
EW PARABOLA
D08
EW TRAPEZIUM
D09
EW CORNER
D10
AFC GAIN
D11
V EHT
D12
H EHT
EX1
FAO VOLUME
EX2
CC-POSITION
EX3
INT
EX4
A-ATT
EX5
TUNER data
EX6
Think chip-Slice LEVEL
OP1
OPTION1
OP2
OPTION2
OP3
OPTION3
M01
INPUT LEVEL
M02
MTS VCO
M03
FILTER
M04
WIDEBAND
M05
SPECTRAL
M06
ANT-B INPUT LEVEL
M07
ANT-B WIDEBAND
M08
ANT-B SPECTRAL
M09
SRS LEVEL
M10
BBE LEVEL
M11
SRS&BBE LEVEL
M12
SRS&BBE OFF LEVEL
M13
SRS Effect
M14
BBE-L Effect
M15
BBE-H Effect
M16
AGC Level
M17
BASS Offset
M18
TREBLE Offset
M19
BASS Offset-BBE
M20
TREBLE Offset-BBE
P01
CONTRAST-PIP
P02
TINT-PIP
P03
COLOR-SAT-PIP
P04
Y-OFFSET-PIP
P05
HXA-PIP
P06
HADJ-PIP
P07
FREE RUN-PIP
P08
TINT-PIP-INPUT
Holding down both the VOL-up and CH-up buttons on the TV set at service mode for more than 2 seconds will
automatically write the above initial values into IC2102.
PART REPLACED
NECESSARY
IC2001
IC201
IC2102
CRT
IC3001
IC1801
DATA
INITIAL VALUE
33(21h)
0-63(00h-3Fh)
14(0Eh)
0-31(00h-1Fh)
12(0Ch)
0-15(00h-0Fh)
2(02h)
0-3 (00h-03h)
7(07h)
0-7 (00h-07h)
3(03h)
0-7 (00h-07h)
36(24h)
0-50(00h-32h)
33(21h)
0-127(00h-7Fh)
122(7Ah)
0-255(00h-FFh)
90(5Ah)
0-127
0(00h)
0-3(00h-03h)
54(36h)
0-255(00h-FFh)
247(F7h)
0-255(00h-FFh)
249(F9h)
0-255(00h-FFh)
15(0Fh)
0-255(00h-FFh)
9(09h)
0-15(00h-0Fh)
36(24h)
0-63(00h-3Fh)
31(1Fh)
0-63(00h-3Fh)
24(18h)
0-63(00h-3Fh)
16(10h)
0-63(00h-3Fh)
9(09h)
0-15(00h-0Fh)
24(18h)
0-63(00h-3Fh)
16(10h)
0-63(00h-3Fh)
255(FFh)
0-255(00h-FFh)
255(FFh)
0-255(00h-FFh)
255(FFh)
0-255(00h-FFh)
255(FFh)
0-255(00h-FFh)
2(02h)
2-3(02h-03h)
8(08h)
0-15(00h-0Fh)
8(08h)
0-15(00h-0Fh)
7(07h)
0-7(00h-07h)
0(00h)
0-31(00h-1Fh)
0(00h)
0-31(00h-1Fh)
0(00h)
0-31(00h-1Fh)
0(00h)
0-31(00h-1Fh)
50(32h)
0-127(00h-7Fh)
41(29h)
0-63(00h-3Fh)
50(32h)
0-127(00h-7Fh)
9(09h)
0-31(00h-1Fh)
10(0Ah)
0-255(00h-FFh)
0(00h)
0-15(00h-0Fh)
11(0Bh)
0-15(00h-0Fh)
36(24h)
0-63(00h-3Fh)
Table - A
ADJUSTMENT
UNNECESSARY
X
X
X
X
X
X
Table - B
ADJUSTMENT CONTENTS
RANGE
Must be set to "27"
Must be set to "0B"
Must be set to "08"
Must be set to "02"
Must be set to "04"
Must be set to "03"
Must be set to "24"
Must be set to "7A"
Must be set to "00"
Must be set to "36"
Must be set to "F7" (32U-F810), "F5" (32U-F500)
Must be set to "F9" (32U-F810), "18" (32U-F500)
Must be set to "0F"
Must be set to "09"
Must be set to "E0"
Must be set to "D9"
Must be set to "D0"
Must be set to "E5"
Must be set to "02"
Must be set to "0F"
Must be set to "0F"
Must be set to "01"
Must be set to "10"
Must be set to "10"
Must be set to "11"
Must be set to "10"
Must be set to "29"
Must be set to "09"
Must be set to "0A"
Must be set to "00"
Must be set to "0B"
Must be set to "24"
NOTES
Data is stored in IC2102.
The adjustment is needed to compensate for characteristics of parts
including IC201 and MTS level (M01).
Holding down both the VOL-up and CH-up buttons on the TV set in
the service mode for more than 2 seconds will automatically write the
above initial values into IC2102. Then perform a complete adjustment.
Adjust items related to picture tube only.
Adjust items related to MTS only (M01~M20).
Adjust items related to P-IN-P only (P01~P08).
9