Smart 101 segment 4 digit led tricolor or mono-color digital bargraph controller with four fully programmable set points for j, k, r, and t type thermocouples and rtd inputs in a switchboard style case

Advertisement

Quick Links

LEOPARD
FAMILY

Specifications

Input Specs: ������������������ Depends on Input signal conditioner
A/D Converter: �������������� 14 bit single slope
Accuracy: ���������������������� ±(0�05% of reading + 2 counts)
Temp. Coeff�: ����������������� 100 ppm/°C (Typical)
Warm up time: ��������������� 2 minutes
Conversion Rate: ���������� 10 conversions per second (Typical)
Digital Display: �������������� 4 digit 0.56" LED red (std), green (optn)
Range -1999 to 9999 counts�
Bargraph Display: ��������� 101 segment 235º circular red (standard),
Green (optional) or tricolor (optional) LED�
Polarity: ������������������������� Assumed positive� Displays - negative
Decimal Selection: �������� Front panel button selectable, X•X•X•X•
Positive Overrange: ������ Bargraph and top segments of digital display
flash�
Negative Overrange: ���� First segment of bargraph and bottom seg-
ments of digital display flash�
Relay Output: ���������������� Two 9 Amp Form C relays, two 4 Amp Form
A relays or 4 x 4 Amp Form A relays
Analog Output: ������������� Isolated 16 bit user scalable mA or V
OIC (mA out) �������������� 4-20 mA @ 0 to 500٠max loop resistance
OIV (volts out) �������������� 0-10 V DC @ 500 ٠or higher resistance
Power Supply: ��������������� AC/DC Auto sensing wide range supply
PS1 (std) �������������������� 85-265 VAC / 95-300 VDC, 50-400Hz 4.2W
PS2 ����������������������������� 18-48 VAC / 10-72 VDC, 50-400Hz 4�2W
Operating Temp�: ���������� 0 to 60°C
Storage Temp: ��������������� -20°C to 70°C
Relative Humidity: �������� 95% (non condensing)
Case Dimensions: �������� Bezel (4.48"x4.48") 113.8x113.8mm
Depth behind bezel (4.23") 107.46 mm
Plus (0�48") 12�24 mm for connectors
Weight: ��������������������������� 16 oz�, 1lb 4 oz when packed
Case Dimensions . . . . . . . . . . . . . . . . . . . . . . 11
Component Layout. . . . . . . . . . . . . . . . . . . . . 11
Connector Pinouts . . . . . . . . . . . . . . . . . . . 10-11
Controls and Indicators . . . . . . . . . . . . . . . . . . 2
CL-B101D40-TCRTD Manual (d0099)
CL-B101D40-TCRTD
Smart 101 segment 4 digit LED Tricolor or Mono-color
digital bargraph controller with four fully programmable
set points for J, K, R, and T type thermocouples and
0.56" LEDs

Table of Contents

Functional Diagram . . . . . . . . . . . . . . . . . . . . 10
General Features . . . . . . . . . . . . . . . . . . . . . . . 1
Ordering Information . . . . . . . . . . . . . . . . . . . 13
Pin Descriptions . . . . . . . . . . . . . . . . . . . . . . . 10
RTD inputs in a switchboard style case.

General Features

External transmitters or signal conditioners can be eliminated by
direct connection of the sensor output to Plug-in Input Signal
Conditioners- available are thermocouples (J, K, R and T types)
or RTD (Pt-100. 385 and 392 curves. 3 wire/4wire). Digitally
Linearized.
Optional isolated 16 bit analog output. User or factory scalable to 4
to 20 mA, 0 to 20 mA or 0 to 10 V across any desired digital span
from ± one count to the full scale range of - 1999 to 9999 (12000
counts).
A Programmable Tricolor (Red-Green-Orange) or mono color (red or
green), 101 segment high brightness bargraph.
Red 4-digit LED display with a range of -1999 to 9999
(12000 counts). Optional green digital display.
Front panel LED annunciators provide indication of setpoint status.
Two 9 Amp Form C, and two 4 Amp Form A or 4 x 4 Amp Form A
relays available.
Auto-sensing AC/DC power supply. For voltages between
85-265 V AC / 95-300 V DC (PS1) or 18-48 V AC / 10-72 V DC
(PS2).
Provision to connect an external programming lockout switch.
Provision for external DIM switch to reduce the brightest
display setting by 50%.
Automatic intelligent averaging, smooths noisy signals while
providing a fast display response to real level changes.

Software Features

• The bargraph can display, full
scale, any desired portion of
the digital reading.
• Setpoint 1 has delay-on-make
and delay-on-break plus
a special "pump on pump
off" mode that creates a
Hysteresis Band between SP1
and SP2.
Programming Conventions. . . . . . . . . . . . . . . . 2
Software Features . . . . . . . . . . . . . . . . . . . . . . 1
Software Logic Tree . . . . . . . . . . . . . . . . . . . . . 3
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . 1
• Four programmable setpoints
with adjustable Hysteresis.•
Bargraph center zero function.
• Relay activation can be select-
ed to occur above (hi) or below
(Lo) each setpoint.
• Digital display blanking.
• Decimal point setting.
• Four-level brightness control
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CL-B101D40-RTD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Texmate CL-B101D40-RTD

  • Page 1: Table Of Contents

    CL-B101D40-TCRTD Smart 101 segment 4 digit LED Tricolor or Mono-color digital bargraph controller with four fully programmable set points for J, K, R, and T type thermocouples and RTD inputs in a switchboard style case. 0.56” LEDs General Features LEOPARD •...
  • Page 2: Controls And Indicators

    Controls and Indicators Front Panel Controls and Indicators Up Button When in the operational display, pressing the button allows you Setpoints indicated 101 Segment Single or to view the setting of the saved Peak and Valley Values. by an OFF Segment Bargraph Tri-color When setting a displayed parameter during programming, the...
  • Page 3: Software Logic Tree

    Software Logic Tree Software Version is Displayed on Power-up The CL-B101D40-TCRTD is an intelligent bargraph meter with a hierarchical software structure designed for easy programming When power is applied, all segments of the bargraph and and operation, as shown below in the software logic tree. digital display light up for 3 seconds.
  • Page 4: Thermocouple And Rtd Type Selection Mode

    Calibration Procedure STEP A Enter the Calibration Mode 1) Press the buttons at the same time. MAIN MENU Display toggles between [CAL] and [oFF]. Operational Display 2) Press the button. Display changes from [oFF] to [on]. 3) Press the button. Sub-menu MODE STEP B...
  • Page 5: Decimal Point And Brightness Selection

    Digital Span Selection For Bargraph Display The bargraph can be set to display full scale (0-101 bars) any portion An example of setting the digital span of the bargraph of the digital reading from a minimum of 100 counts to a maximum of display to be different than 12,000 counts.
  • Page 6: Bargraph Center Point Display Mode Selection

    Digital Span Selection for Analog Range Output Digital Span Selection for Analog Range Output STEP E Selecting the [Anhi] Digital Value for Analog High Output 1) Using the buttons, adjust the display to the desired From Decimal Point and DIGITAL SPAN SELECTION Brightness Selection digital value at which the [chi] Calibrated Analog High output will FOR ANALOG RANGE OUTPUT...
  • Page 7: Two Point Analog Range Setting & Calibration

    Two Point Analog Output Range Setting and Calibration Two Point Analog Output Range Setting and Calibration Determine if the Analog Output Selection Header is in the 4 to 20mA (0-20mA) position or the 0 to 10VDC position. If necessary, the mod- ule may have to be removed and the header position changed (see Operational Display Component Layout below).
  • Page 8: Setpoint Setting & Relay Conf. Mode

    Setpoint Setting and Relay Configuration Mode The following programming steps are required to enter the setpoint values and configure the relay functions Operational Display in a meter with four relays using four setpoints� Generally if less than four relays are installed, the setpoints without relays are operational in software for tri-color control or display only purposes�...
  • Page 9: Bargraph Color Programming Mode

    Setpoint Setting and Relay Configuration Mode Continued STEP M Set Relay Activation mode [rLYS] for SP1 (h) High the relay energizes when the setpoint is exceeded. (L) Low the relay energizes below From From Step L of Setpoint Setting and Relay the setpoint.
  • Page 10: Connector Pinouts

    Connector Pinouts Connector Pinouts Pinout Diagram Standard plug-in screw terminal connectors provided by Texmate: The Rear View of the Meter diagram shows the meter with the relay configuration: dual 9 Amp Form C and dual 4 Amp Form A relays� An analog output module is also shown as installed�...
  • Page 11: Component Layout

    Connector Pinouts continued Relay Modules with 2 Non-Isolated 4A Form A Relays, AC/DC Power Input- Pins 14 and 15 and 2 Non-Isolated 9A Form C Relays Auto-sensing AC/DC power supply� For voltages between 85-265 V AC/95-300 V DC (PS1) or 18-48 V AC/10-72 V DC (PS2). DL Series Pin 14 AC/DC Neutral.
  • Page 12: Case Dimensions

    Input Module Calibration Procedure IT10 Thermocouple Input Signal Conditioner installed. 1� The cold junction select header must be installed in the 6. Apply an input corresponding to the maximum reading of correct position for the thermocouple type to be used� the thermocouple and adjust the SPAN Potentiometer to Thermocouple types J, K, R and T are supported�...
  • Page 13: Ordering Information

    However, normal use and service for a period of one year from date of shipment. Texmate’s obligations since we have no control over the use of our products once they are shipped, NO WARRANTY...

Table of Contents