Make Electrical Connections - GE CT9070SHSS Installation Instructions Manual

30” french door wall ovens
Table of Contents

Advertisement

Available languages

Available languages

3
ELECTRICAL REQUIREMENTS (CONT.)
This appliance must be supplied with the proper voltage and frequency and connected to an individual,
properly grounded branch circuit, protected by a circuit breaker or fuse. See the rating plate located on the
oven frame to determine the rating of the product.
Rating plate
is located on
left side trim
Use the chart below to determine the minimum recommended dedicated circuit protection:
KW Rating
240V
4.9 KW–7.2 KW
7.3 KW–9.6 KW
9.7 KW–12.0 KW
8.4 KW–10.4 KW
DO NOT shorten the flexible conduit. The conduit strain relief clamp must be securely attached to the
junction box and the flexible conduit must be securely attached to the clamp. If the flexible conduit will not
fit within the clamp, do not install the oven until a clamp of the proper size is obtained.
The 3 power leads supplied with this appliance are suitable for connection to heavier gauge household
wiring. The insulation of these 3 leads is rated for temperatures much higher than the temperature rating of
the household wiring. The current-carrying capacity of the conductor is governed by the wire gauge and the
temperature rating of the insulation around the wire.
Recommended
KW Rating
Circuit Size
208V
(Dedicated)
4.2 KW–6.2 KW
30 Amp
6.3 KW–8.3 KW
40 Amp
50 Amp
4

MAKE ELECTRICAL CONNECTIONS

WARNING:
means to prevent power from being switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device, such as a tag,
to the service panel.
Place oven on table or platform even with the cutout opening. For a French Door oven, the platform must
support 220 lbs. (98.8 kg). Connect the flexible conduit to the electrical junction box as shown below*.
Connected
Position the conduit in such a manner that it will lie behind the unit in a natural loop when the oven is
Appliance
installed. You will need to purchase an appropriate strain relief clamp to complete the connection of the
Information
conduit to the junction box.
is located on
right side trim
Place Oven on a
Support to Assist in
Connecting Conduit
* Ovens come equipped with a 40" long conduit. If a longer conduit is desired, there may be one available for
your model. To check availability or order parts, call 1.800.GE.CARES.
Switch power off at the service panel and lock the service disconnecting
Junction Box
Conduit
Bare
Ground
Strain Relief Clamp
(not included) Must Be
Used at Junction Box
Ground
Wire
Red
White
Black

Advertisement

Table of Contents
loading

Table of Contents