Wall-mounting the appliance and levelling it
First remove the protective film from the back of the
1.
appliance and, following installation, remove the rest
of the film.
When mounting the appliance, ensure that it
2.
engages properly with the mounting supports.
If required, the appliance can be moved to the right
3.
or to the left.
Firmly tighten the screws for the mounting supports.
4.
Hold the bracket firmly when doing so.
If no duct is to be fitted, screw in the two locking
5.
screws without the bracket.
Connecting the pipes
If the extractor hood is to be operated in exhaust-air
mode, the pipes must be connected. If the extractor
hood is to be operated in air-recirculation mode, an
optional accessory must be fitted. To do this, refer to
the installation instructions provided.
Note:
If an aluminium pipe is being used, smooth the
connection area beforehand.
Exhaust air pipe, dia. 150 mm (recommended size)
Fit the exhaust air pipe directly to the air-pipe connector
and seal the joint.
Exhaust air pipe, dia. 120 mm
Fit the reducing connector directly to the air-pipe
1.
connector.
Attach the exhaust air pipe to the reducing
2.
connector.
Use suitable means to seal both joints.
3.
Attaching the flue duct
If the extractor hood is to be operated in exhaust-air
mode, a flue duct must be fitted.
The flue duct does not need to be fitted for air-
recirculation mode.
:
Warning – Risk of injury!
From sharp edges during installation. Always wear
protective gloves while installing the appliance.
¨
©
:
Warning – Risk of electric shock!
Components inside the appliance may have sharp
edges. These may damage the connecting cable. Do
not kink or pinch the connecting cable during
installation.
Separate the flue duct sections by removing the
1.
adhesive tape.
Remove the pieces of protective film from both flue
2.
duct sections.
Push one flue duct section into the other.
3.
Notes
– To prevent scratches, lay paper over the edges of
the outer flue duct section to protect the surface.
– The slots of the inner flue duct section point
downwards.
Place flue ducts sections on the appliance.
4.
Slide the inner flue duct section upwards, attach it to
5.
the left and right sides of the retaining bracket, and
then slide it down to engage it.
Screw the flue duct section to the sides of the
6.
retaining bracket using two screws.
Clip the lower flue duct section in at the retaining
7.
bracket. The connection cable must not be
ª
damaged.
Note:
If an air-recirculation optional accessory has been
fitted and the extractor hood is to be operated without a
flue duct, the cable must be wound onto the connector.
Installation
en
¨
©
23