Advertisement

Quick Links

LTR50001006, Rev. P
1/1/21

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FRP-910-3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Cal Flame FRP-910-3

  • Page 1 LTR50001006, Rev. P 1/1/21...
  • Page 2: Table Of Contents

    This product and the fuels used to op- strictly prohibited. erate this product (propane or natural Cal Flame ® is a registered trademark. gas), and the products of combus- Due to continuous improvement programs, tion of such fuels, can expose you to...
  • Page 3 Safety Instructions Cal Flame fireplaces are designed for outdoor use only . Do not store combustible materials, gasoline and any other flammable vapors and liquids. A propane gas cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
  • Page 4 Operation • Do not use charcoal or other solid fuel in a gas burning fireplace. • Do not operate the fireplace with the propane tank on, near, or un- der the hearth! This could result in fire, explosion, or severe injury. •...
  • Page 5 Maintenance and Repair • Spiders and other insects can nest in the burners and block the gas and airflow to the burner ports. This creates a dangerous condi- tion that can result in a fire from behind the valve panel. Inspect and clean the burners periodically and follow the guidelines in the maintenance section of this manual.
  • Page 6 Storage • When your fireplace is not in use, turn off the gas at the source. • Do not store the propane cylinder in the vicinity of this or any other appliance when it is not being used. • This appliance can be store indoors only if it has been discon- nected from its fuel supply.
  • Page 7: Installation / Assembly

    Installation / Assembly Most cities and counties require permits for exterior construction and electrical circuits. In addition, some communities have codes requiring residential barriers such as fencing and/or self-closing gates on prop- erty to prevent unsupervised access to the property by children under the age of 5.
  • Page 8: Placement And Location

    Placement and Location Cal Flame fireplaces are designed for outdoor use only . • Never locate this appliance in a building, garage, or any other en- closed room or under a sealed overhead structure, or in any type of enclosed area such as a garage, shed, or breezeway. Keep clear of trees and shrubs.
  • Page 9: Leak Testing Procedure

    Leak Testing Procedure Perform a leak test at least once a year whether the gas supply cylinder has been disconnected or not. In addition, whenever the gas cylinder is connected to the regulator or whenever any part of the gas system is disconnected or replaced, perform a leak test.
  • Page 10: Liquid Propane

    Liquid Propane Your Cal Flame fireplace is not provided with a propane cylinder. If you choose to operate your fireplace with propane, you must supply your own cylinder. Requirements The 20 lb propane gas supply cylinder used with propane models must be con- structed and marked in accordance with the specifications for propane gas cylinders as required by the U.S.
  • Page 11 Connection Check the rating plate to make sure the gas supply you are hooking up to is the gas type the fireplace is manufactured for. Inspect the hose shipped with the unit for damage. Never attempt to use damaged or plugged equipment. See your local liquid propane gas dealer for repairs.
  • Page 12: Propane Cylinder Enclosure

    Propane Cylinder Enclosure Cal Flame fireplaces do not have an enclosure for the propane cylinder. If you build an enclosure for a propane gas cylinder, follow these rec- ommended specifications and follow local codes. Ensure cylinder valves are always readily accessible. A door on the en- closure to gain access to the cylinder valve is acceptable, provided it is non-locking and can be opened without the use of tools.
  • Page 13 2) All sides are completely enclosed. This method requires at least two ventilation openings at cylinder valve level in the side wall, equally sized, spaced at 180 degrees (3.14 rad), and unobstructed. Make sure each opening has a total free area of not less then ½...
  • Page 14: Natural Gas

    Natural Gas Ensure that the service supplying the fireplace is fitted with a conve- niently positioned shut off valve with easy access. The shut off valve MUST NOT be inside the appliance! Requirements Always check the rating plate to make sure the gas supply you are hooking up to is the gas type the fireplace is manufactured for.
  • Page 15: Fireplace Burner Installation

    Fireplace Burner Installation This procedure describes how to access the gas lines for installation. Gas installation should be performed by a qualified contractor. 1. Remove the burner from the hearth. It is not con- nected and will lift out easily. 2.
  • Page 16 4. Slide the flex line and the 5. Reach through the gap in the black sparker wires into the open right side and pull the gap in the hearth base. flex line and black sparker wires. 6. Connect the black sparker 7.
  • Page 17 9. Connect the LP or NG gas 10. Replace the right side refrac- source gas line to the gas tory wall. valve as shown below. 11. Unscrew the push button switch and insert the battery in the starter. Caution! Never place or store the propane tank under the hearth base! Fireplace Owner’s Manual LTR50001006, Rev.
  • Page 18: Fireplace Log Set Placement

    Fireplace Log Set Placement The log set, log grate and crushed lava rock are shipped together on applicable models. Remove the log set and unpack all components. The logs are fragile -- use care when handling. Once the fireplace is in position, level and safely hooked up to the proper fuel supply, install the log grate over the plate burner.
  • Page 19: High Elevation Installation

    To The Authorized Gas Appliance Installer: All Cal Flame fireplaces are shipped from the factory equipped to burn on liquid propane fuel. Enclosed with this kit is a natural gas conversion kit for converting this unit to natural gas. To perform this conversion, follow the directions below and to the local regulation standards in your area.
  • Page 20 burn and as a general rule, the air shutter for propane installation should be completely open, and the air shutter for NG installation should be mostly closed. This can be adjusted later to create a clean and desired flame. 5. Refer to photo below for proper placement of parts. The washer should insert next to the protective screen cover, then the spring is to be aligned with the hole and finally the natural gas orifice is to be threaded into the end of the fuel inlet leading into the burner.
  • Page 21: Operation

    Operation WARNING: DO NOT use solid fuel, such as wood or charcoal, in a gas fueled fireplace. Upon completing the gas line connection, If you do not a small amount of air will be in the lines. follow these When the first lighting the burner, it will instructions exactly, take a few seconds for the lines to purge a fire or explosion...
  • Page 22 and replace any part of the control system and any gas control which has been under water. • Make sure the ignitor battery has been installed properly. Ignitor will not operate properly without a battery installed. Lighting Instructions for Automatic Starter 1.
  • Page 23 the unit and then turn the valve on the propane tank to the OFF posi- tion clockwise. NOTE The propane regulator in this appliance is equipped with a low flow protection device. Unless the propane cylinder valve is opened before the valve, the gas flow will be reduced resulting in a very small flame.
  • Page 24: Cleaning And Maintenance

    Cleaning and Maintenance Inspect the appliance before initial use. Clean the appliance at least annually and have it inspected by a qualified field service person. Periodically remove the logs and examine the burner. If the burner is dirty, clean it with a soft wire brush. Also examine the area around the burner air shutter.
  • Page 25: Replacement Parts

    Replacement Parts Call 1-800-225-7727 for any replacement parts not listed below. Be sure to have model name and number available. Replacement parts shown below are listed first as complete assemblies with individual parts that can be ordered separately. Fiberglass firebox assembly 36” set of 5 pieces BBQ08210622 Left panel for 36”...
  • Page 26: Specifications

    Specifications Propane Gas Natural Gas Max . Input BTU/ 55,000 49,000 Orifice Size #43 (0.089) 1/8” (.125) Manifold Pressure 10” Water Column 7” Water Column Maximum Gas 11” Water Column 14” Water Column Supply Pressure Maximum Inlet 13” Water Column 14”...
  • Page 27 Fireplace Owner’s Manual LTR50001006, Rev. P www.cal amebbq.com...
  • Page 28 Fireplace Owner’s Manual LTR50001006, Rev. P www.cal amebbq.com...
  • Page 29: Limited Warranty

    90 days. Extent of Warranty This limited warranty is only valid on Cal Flame models delivered in the United States or Canada and extends through the selling dealer to the original purchaser at the original site of installation. This warranty be- comes valid at time of delivery and ends either by specified time-frame listed above or upon owner transfer or relocation.
  • Page 30 Warranty Limitations and Exclusions Grate and log set are not covered by this warranty. This warranty is void if the fireplace has been subject to negligence, al- teration, misuse, repairs, dings, dents, scratches, or incorrect and / or prohibited applications, as specified in the owner’s manual. Gas lines must be installed by a licensed plumber only or local gas company agent.
  • Page 31 LMS Customer Service Department at 1462 E. Ninth St., Pomona CA 91766 or call (800) 225-7727. See your Cal Flame dealer for a copy of the applicable warranty, details and any questions you may have regarding the warranty coverage on your product.
  • Page 32 CONTACT INFORMATION For customer service, please contact your authorized dealer immediately. If you need additional information and/or assistance, please contact: Cal Flame Customer Service Department 1462 East Ninth Street Pomona, CA 91766 Toll Free: 1-800-225-7727 Fax: 1-909-629-3890 www.calflamebbq.com WARNING! Proposition 65 Warning: Handling the brass...