Periodic Maintenance; Foreword To Maintenance; Cleaning The Filter Silencer; Fig. 20: Cleaning The Filter Silencer (1) - ABB HT575751 Operation Manual

Table of Contents

Advertisement

Operation Manual / 4 Product description / A100-M axial
6 Periodic maintenance / 6.1 Foreword to maintenance
6

Periodic maintenance

6.1

Foreword to maintenance

Maintenance work includes regular visual controls and cleaning operations which are inten-
ded to ensure the trouble-free functioning of the turbocharger.
6.2

Cleaning the filter silencer

Fig. 20: Cleaning the filter silencer (1)
81135
Filter silencer body
81136
Absorption segment
81137
Sheet-metal covering
81265
Filter ring (if present)
E
Insert unit = absorption segment + sheet-metal covering
Cleaning the filter ring (if present)
Remove filter ring (81265).
u
Clean filter ring (81265) as required or every 500 hours of operation and replace after the
u
fifth cleaning process at the latest.
Contamination of the filter ring depends on the degree of purity of the sucked-in air.
Rinse the filter ring (81265) with water and mild detergent or, in the case of heavy con-
u
tamination, soak and carefully push through. Rinse in cold water. Avoid high mechanical
loads (water jet).
Let the filter ring dry completely before assembling.
u
Dirty water and mild detergent must be disposed of in compliance with locally applicable
u
regulations.
© Copyright 2017 ABB. All rights reserved.
81266
Cover grid
81269
Connecting rods
81272
Screw
81273
Lock nut
HZTL4033_DE
Revision B
December 2017

Advertisement

Table of Contents
loading

This manual is also suitable for:

A170-m62