You have purchased the AIMS Power 12V/24V AC Converter and Battery Charger. This product will bring you reliable power when used and maintained properly. This manual provides safety guidelines, detailed planning and setup information, installation procedures, as well as information about operating and troubleshooting the unit.
Page 4
eyes. Wear complete eye protection and clothing protection. Avoid touching eyes while working near battery. If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters eye, immediately flood eye with running cold water for at least 10 minutes and get medical attention immediately.
The AIMS Power AC Converter / Battery Charger 12V/24V is ideal for applications that require diverse ways of recharging batteries. There are many ways to recharge batteries and the wide AC input range of this unit accommodates most applications and battery technologies. Useful with generators and shore power, this converter charges various types of batteries such as, open lead acid, AGM, Gel and LiFePO4.
Figure 1 Front Panel Main Switch ON: Once the unit has been properly installed and batteries are connected,flip the switch to “ON”, the unit will turn on automatically, and work according to the input AC source’s status. OFF:Flip the switch to “OFF”, the unit will turn off. BTS Port Connect the BTS to this port.
Figure 2 Rear Panel LED Indicator The unit has green, yellow and red LEDs to indicate the operating status of the AC converter. Table 1 – 1: LED status indicator Conditions Red(Fault RED) Yellow(Status YEL) Green(Status GRN) Mode select fault Blinking 0.5s Blinking 0.5s Blinking 0.5s...
Input terminal The unit can accept input voltages ranging from 70Vac – 145Vac. CAUTION Before connecting, power off the unit and make sure the AC cord is not plugged into an AC outlet. – – Step 1- Follow battery polarity guide located near battery terminal! Place the battery cable ring terminal over AC Converter / Battery Charger’s battery terminal.
Figure 2: Single battery connection 2) Series battery connection: When using multiple batteries in series, all batteries must equal in voltage and amp hour capacity, and the sum of their voltages must be equal to the voltage of unit’s nominal input voltage.
On the heat sink of DC-DC part should be Red LED Blinking 2s over temperature operate below 105°C If any other situations occur that are not listed above, call AIMS Power immediately. 96-145VAC full performance Input Voltage 70-96VAC automatically de-rate to 50% of full load current...
Page 11
Unit must be safe for input voltage up to 150VacRMS (and up Input Over Voltage to 215Vpeak), need not be operating. Above this level the unit may be damaged. Non-destructive reverse battery polarity protection with fuses. Reverse Battery Polarity Protection Unit shall not sustain damage and shall meet all specifications after fuse replacement.