R182-M80 3rd Gen. Intel® Xeon® Scalable DP Server System - 1U 8-Bay Gen4 NVMe User Manual Rev. 1.0...
Page 2
GIGABYTE's prior written permission. Documentation Classifications In order to assist in the use of this product, GIGABYTE provides the following types of documentation: User Manual: detailed information & steps about the installation, configuration and use of this product (e.g.
Page 3
Conventions The following conventions are used in this user's guide: NOTE! Gives bits and pieces of additional information related to the current topic. CAUTION! Gives precautionary measures to avoid possible hardware or software problems. WARNING! Alerts you to any damage that might result from doing or not doing specific actions.
Page 4
Server Warnings and Cautions Before installing a server, be sure that you understand the following warnings and cautions. WARNING! To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
Page 5
Electrostatic Discharge (ESD) CAUTION! ESD CAN DAMAGE DRIVES, BOARDS, AND OTHER PARTS. WE RECOMMEND THAT YOU PERFORM ALL PROCEDURES AT AN ESD WORKSTATION. IF ONE IS NOT AVAILABLE, PROVIDE SOME ESD PROTECTION BY WEARING AN ANTI-STATIC WRIST STRAP AT- TACHED TO CHASSIS GROUND -- ANY UNPAINTED METAL SURFACE -- ON YOUR SERVER WHEN HANDLING PARTS.
Page 6
CAUTION! Risk of explosion if battery is replaced incorrectly or with an incorrect type. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used bat- teries according to the manufacturer’s instructions.
Chapter 1 Hardware Installation Installation Precautions The motherboard/system contain numerous delicate electronic circuits and components which can become damaged as a result of electrostatic discharge (ESD). Prior to installation, carefully read the user manual and follow these procedures: • Prior to installation, do not remove or break motherboard S/N (Serial Number) sticker or warranty sticker provided by your dealer.
Product Specifications NOTE: We reserve the right to make any changes to the product specifications and product-related information without prior notice. System 438 x 43.5 x 730 (W x H x D, mm) Dimension 3rd Generation Intel® Xeon® Scalable Processors ...
Page 13
Internal I/O 2 x SATA 7-pin connectors 2 x CPU fan headers 1 x USB 3.0 header 1 x TPM header 1 x VROC connector 1 x Front panel header 1 x HDD back plane board header ...
Page 14
System Aspeed® AST2600 management controller Management GIGABYTE Management Console (AMI MegaRAC SP-X) web interface Dashboard HTML5 KVM Sensor Monitor (Voltage, RPM, Temperature, CPU Status …etc.) Sensor Reading History Data FRU Information SEL Log in Linear Storage / Circular Storage Policy ...
Chapter 2 System Appearance Front View HDD4 HDD5 HDD6- HDD7 HDD0 HDD1 HDD2 HDD3 Description Front USB 3.0 Ports Front Panel LEDs and Buttons 2.5" HDD Bays 3.5" HDD Bays Green HDD Latches Support NVMe 2-3 Front Panel LED and Buttons •...
Rear View PSU2 PSU1 Description PCIe Card Slot x 2 Mezzanine Card Slot (Option/OCP 3.0/SFF) ID Button with LED 10/100/1000 Server Management LAN Port GbE LAN Port x 2 USB 3.0 Port x 2 Mezzanine Card Slot (Option/OCP 2.0) VGA Port System Appearance - 18 -...
Front Panel LED and Buttons No. Name Color Status Description Press the button server generates a NMI to the processor NMI button if the multiple-bit ECC errors occur, which effectively halt the server. Reset Button Press the button to reset the system. ID Button Press the button to activate system identification Green...
Rear System LAN LEDs Name Color Status Description Yellow 1 Gbps data rate 1GbE Green 100 Mbps data rate Speed LED 10 Mbps data rate Link between system and network or no access 1GbE Green Link/ Activity Blink Data transmission or receiving is occurring No data transmission or receiving is occurring System Appearance - 20 -...
Power Supply Unit (PSU) LED PSU LED State Description No AC power to all power supplies 1Hz Green Blinking AC present / only standby on / Cold redundant mode 2Hz Green Blinking Power supply firmware updating mode AC cord unplugged or AC power lost; with a second power supply in parallel still with AC input power Amber Power supply critical event causing shut down:...
Hard Disk Drive LEDs LED1 LED2 LED1 LED2 HDD Present RAID SKU Rebuilding LED1 Locate HDD Fault Access (No Access) Disk LED Green ON(*1) BLINK (*2) (LED on Back Panel) Amber No RAID configuration Green ON(*1) (via PCH, HBA) Removed HDD Slot (LED on Back Panel) Amber Green...
Chapter 3 System Hardware Installation Pre-installation Instructions Computer components and electronic circuit boards can be damaged by electrostatic discharge. Working on computers that are still connected to a power supply can be extremely dangerous. Follow the simple guidelines below to avoid damage to your computer or injury to yourself.
Removing Chassis Cover Before you remove or install the system cover • Make sure the system is not turned on or connected to AC power. Follow these instructions to remove the chassis cover: Remove the screw securing the chassis cover. Push button to unlock the handle.
Removing and Installing the Fan Duct Follow these instructions to remove/install the fan duct: Lift up to remove the two fan duct. To install the fan duct, align the fan duct with the guiding groove. Push down the fan duct into chassis until its firmly seats.
Removing the Heat Sink Follow these instructions to remove/install the heatsink: Loosen the captive screws securing the heatsink in place in reverse order (4g3g2g1). Move the rotating wires into the unlatch position. Lift and remove the heat sink from the system. To reinstall the heat sink reverse steps 1-3 while ensuring that you tighten the captive screws in sequential order (1g2g3g4) as seen in the image below.
Installing the CPU Read the following guidelines before you begin to install the CPU: • Make sure that the motherboard supports the CPU. • Always turn off the computer and unplug the power cord from the power outlet before installing the CPU to prevent hardware damage.
Installing the Memory Read the following guidelines before you begin to install the memory: • Make sure that the motherboard supports the memory. It is recommended that memory of the same capacity, brand, speed, and chips be used. • Always turn off the computer and unplug the power cord from the power outlet before installing the memory to prevent hardware damage.
3-5-2 Installing the Memory Before installing a memory module, make sure to turn off the computer and unplug the power cord from the power outlet to prevent damage to the memory module. Be sure to install DDR4 DIMMs on this motherboard. Follow these instructions to install the Memory: Insert the DIMM memory module vertically into the DIMM slot, and push it down.
3-5-5 Intel Optane DCPMM DIMM Population Rule Thermal conditions for DCPMM DIMM support: • The ambient temperature must be at or below 35°C • The 3rd Generation Intel® Xeon® Scalable Processors used must have a maximum TDP of 270W • A maximum of 16 pcs 512G DCPMM may be installed •...
Installing the PCI Expansion Card • Voltages can be present within the server whenever an AC power source is connected. This voltage is present even when the main power switch is in the off position. Ensure that the system is powered-down and all power sources have been disconnected from the server prior to installing a PCIe card.
Installing the Mezzanine Card 3-7-1 OCP 3.0 Use of the following type of OCP 3.0 NIC is recommended: • OCP 3.0 SFF with Pull Tab • OCP 3.0 SFF with Ejector Latch Follow these instructions to install an OCP 3.0 mezzanine card: Remove the two screws securing the mezzanine card slot cover.
3-7-2 OCP 2.0 Follow these instructions to install an OCP 2.0 mezzanine card: Loosen the thumbscrew on the riser bracket Lift up the riser bracket out of system. Remove the screw securing the mezzanine card slot cover. Remove the slot cover from the system. Install the OCP 2.0 slot cover to the system Secure the OCP 2.0 slot cover with the screw.
Installing the Hard Disk Drive Read the following guidelines before you begin to install the hard disk drive: • Take note of the drive tray orientation before sliding it out. • The tray will not fit back into the bay if inserted incorrectly. •...
Page 37
Follow these instructions to install a 2.5" hard disk drive into 3.5" HDD Tray: Press the release button. Extend the locking lever. Pull the locking lever in the direction indicated to remove the HDD tray. Align the hard disk drive with the positioning screw on the HDD tray. Secure the hard disk drive with five screws.
Installing the M.2 Device and Heat Sink WARNING: Installation of the thermal pad over the M.2 device is required when installing an M.2 device. Lack of the thermal pad may result in the system overheating and throttle the system performance. CAUTION The position of the stand-off screw will depend on the size of the M.2 device.
3-10 Replacing the Fan Assembly • Voltages can be present within the server whenever an AC power source is connected. This voltage is present even when the main power switch is in the off position. Ensure that the system is powered-down and all power sources have been disconnected from the server prior to replacing a system fan.
3-11 Replacing the Power Supply Follow these instructions to replace the power supply: Press the retaining clip on the right side of the power supply along the direction of the arrow. Pull out the power supply handle at the same time and pull out the power supply. Insert the replacement power supply firmly into the chassis.
3-12 Cable Routing Front Switch Cable/Front LED Cable Front Panel USB 3.0 Cable - 41 - System Hardware Installation...
Page 42
HDD Backplane Board Power Cable HDD Backplane Board Signal Cable - 42 - System Hardware Installation...
Page 43
Motherboard to HDD Back Plane Board Signal Cable (SATA0) SATA0 Motherboard to HDD Back Plane Board Signal Cable (SATA1) SATA1 - 43 - System Hardware Installation...
Page 44
U.2 NVMe to HDD Back Plane Board Cable (U.2_0 /U.2_1/U.2_2/U.2_3) - 44 - System Hardware Installation...
Chapter 4 Motherboard Components Motherboard Components 19 20 21 CPU0 CPU1 Item Description HDD Back Plane Board Connector Slimline SAS Connector (U2_P0_0/PCIe Gen4 Signal) Slimline SAS Connector (U2_P0_1/PCIe Gen4 Signal) Front Panel USB 3.0 Connector Front Panel Connector IPMB Connector 2 x 4 GPU Card Power Connector (P12V_GPU2) 2 x 4 GPU Card Power Connector (P12V_GPU3) 2 x 4 GPU Card Power Connector (P12V_GPU1)
Page 46
BMC Firmware Readiness LED System Battery Riser Connector #1 (SLOT1/PCIe Gen4/x32 Slot) SATA DOM Support Power Connector (for SSATA5) SATA Connector (SSATA5) SATA DOM Support Power Connector (for SSATA4) SATA Connector (SSATA4) Slimline SAS Connector (SSATA0/SATA 6Gb/s) Slimline SAS Connector (SATA0/SATA 6Gb/s) Slimline SAS Connector (SATA1/SATA 6Gb/s) VROC Upgrade Module Connector TPM Module Connector (SPI Interface)
Backplane Board Storage Connector 4-3-1 CBP1044 Item Description SATA Connector (SATA0) SATA Connector (SATA1) SATA Connector (SATA2) SATA Connector (SATA3) 4-3-2 CBP1045 Item Description SlimLine SAS Connector (U.2_0) SlimLine SAS Connector (SATA0_1) SlimLine SAS Connector (U.2_1) SlimLine SAS Connector (U.2_2) SlimLine SAS Connector (SATA2_3) SlimLine SAS Connector (U.2_3) Motherboard Components...
Chapter 5 BIOS Setup BIOS (Basic Input and Output System) records hardware parameters of the system in the EFI on the motherboard. Its major functions include conducting the Power-On Self-Test (POST) during system startup, saving system parameters, loading the operating system etc. The BIOS includes a BIOS Setup program that allows the user to modify basic system configuration settings or to activate certain system features.
Page 50
Main This setup page includes all the items of the standard compatible BIOS. Advanced This setup page includes all the items of AMI BIOS special enhanced features. (ex: Auto detect fan and temperature status, automatically configure hard disk parameters.) ...
The Main Menu Once you enter the BIOS Setup program, the Main Menu (as shown below) appears on the screen. Use arrow keys to move among the items and press <Enter> to accept or enter other sub-menu. Main Menu Help The on-screen description of a highlighted setup option is displayed on the bottom line of the Main Menu.
Page 52
Parameter Description BIOS Information Project Name Displays the project name information. Project Version Displays version number of the BIOS setup utility. Build Date and Time Displays the date and time when the BIOS setup utility was created. BMC Information (Note1) BMC Firmware Version Displays BMC firmware version information.
Page 53
Parameter Description Memory Frequency Displays the frequency information of the installed memory. (Note2) Onboard LAN Information LAN1 MAC Address (Note3) Displays LAN MAC address information. LAN2 MAC Address (Note3) Displays LAN MAC address information. System Date Sets the date following the weekday-month-day-year format. System Time Sets the system time following the hour-minute-second format.
Advanced Menu The Advanced Menu displays submenu options for configuring the function of various hardware components. Select a submenu item, then press <Enter> to access the related submenu screen. When Boot Mode Select is set to UEFI (Default) When "Boot Mode Select" is set to Legacy in the Boot > Boot Mode Select section - 54 - BIOS Setup...
5-2-1 Trusted Computing Parameter Description Configuration Enable/Disable BIOS support for security device. OS will not show security device. TCG EFI protocol and INT1A interface will not be Security Device Support available. Options available: Enable, Disable. Default setting is Enable. - 55 - BIOS Setup...
5-2-2 Serial Port Console Redirection Parameter Description Console redirection enables the users to manage the system from a COM1 Console remote location. Redirection (Note) Options available: Enabled, Disabled. Default setting is Disabled. Press [Enter] to configure advanced items. Please note that this item is configurable when COM1 Console Redirection is set to Enabled.
Page 57
Parameter Description Parity – A parity bit can be sent with the data bits to detect some transmission errors. – Even: parity bit is 0 if the num of 1's in the data bits is even. – Odd: parity bit is 0 if num of 1's in the data bits is odd. –...
Page 58
Parameter Description Legacy Console Redirection Press [Enter] to configure advanced items. Redirection COM Port – Selects a COM port for Legacy serial redirection. – Default setting is COM1. Resolution – Selects the number of rows and columns used in Console Redirection for legacy OS support.
Page 59
Parameter Description Flow Control EMS – Flow control can prevent data loss from buffer overflow. When sending data, if the receiving buffers are full, a 'stop' signal can Serial Port for Out-of-Band be sent to stop the data flow. Once the buffers are empty, a 'start' EMS Console Redirection signal can be sent to re-start the flow.
5-2-3 SIO Configuration Description Parameter Displays the AMI SIO driver version information. AMI SIO Driver Version Super IO Chip Logical Device(s) Configuration Press [Enter] to configure advanced items. Use This Device – When set to Enabled allows you to configure the serial port settings. When set to Disabled, displays no configuration for the serial port.
5-2-4 PCI Subsystem Settings Parameter Description PCI Bus Driver Version Displays the PCI Bus Driver version information. When enabled, this setting will initialize the device expansion PCI Express Slot # I/O ROM (Note1) ROM for the related PCI-E slot. Options available: Enabled, Disabled. Default setting is Enabled. Enable/Disable the onboard LAN1/ LAN2 controller.
5-2-5 USB Configuration Parameter Description USB Configuration USB Devices: Displays the USB devices connected to the system. Enable/Disable the XHCI (USB 3.0) Hand-off support. XHCI Hand-off Options available: Enabled, Disabled. Default setting is Enabled. USB Mass Storage Driver Enable/Disable the USB Mass Storage Driver Support. Support Options available: Enabled, Disabled.
5-2-9 Chipset Configuration Parameter Description Defines the power state to resume to after a system shutdown that is due to an interruption in AC power. When set to Last State, the system will return to the active power state prior to shutdown. When set to Restore on AC Power Loss (Note) Power Off, the system remains off after power shutdown.
5-2-10 Tls Auth Configuration Parameter Description Press [Enter] for configuration of advanced items. Enroll Cert – Press [Enter] to enroll a certificate • Enroll Cert Using File • Cert GUID Server CA Configuration Input digit character in 1111111-2222-3333-4444-1234567890ab format. –...
Page 70
Description Parameter Press [Enter] to configure advanced items. Link Speed – Allows for automatic link speed adjustment. – Options available: Auto Negotiated, 10 Mbps Half, 10 Mbps Full, 100 Mbps Half, 100 Mbps Full. Default setting is Auto Negotiated. Wake On LAN NIC Configuration ...
5-2-13 VLAN Configuration Parameter Description Press [Enter] to configure advanced items. Create new VLAN VLAN ID – Sets VLAN ID for a new VLAN or an existing VLAN. – Press the <+> / <-> keys to increase or decrease the desired values. –...
Chipset Menu Chipset Setup menu displays submenu options for configuring the function of Platform Controller Hub(PCH). Select a submenu item, then press <Enter> to access the related submenu screen. - 73 - BIOS Setup...
Description Parameter Processor Configuration Press [Enter] to configure advanced items. CPU Socket 0/1 Configuration – Core Disable Bitmap(Hex) • Number of Cores to enable. 0 means all cores. FFFFFFF Pre-Socket Configuration means to disable all cores. The maximum value depends on the number of CPUs available.
Page 76
Description Parameter Options available: Enable, Disable. Default setting is Disable. Debug Consent Enable/Disable total memory encryption (TME). Total Memory Encryption (TME) Options available: Enabled, Disabled. Default setting is Disabled. - 76 - BIOS Setup...
5-3-2 Common RefCode Configuration Parameter Description Common RefCode Configuration Selects the MMIO High Base setting. MMIO High Base Options available: 56T, 40T, 32T, 24T, 16T, 4T, 2T, 1T, 512G, 3584T. Default setting is 56T. Selects the allocation size used to assign memory-mapped I/O (MMIO) resources.
5-3-3 UPI Configuration Description Parameter Press [Enter] to configure advanced items. Uncore Status – Press [Enter] to view the Uncore status. Link Frequency Select – Selects the UPI link frequency. – Options available: 9.6GT/s, 10.4GT/s, 11.2GT/s, Auto. Default setting is Auto.
5-3-4 Memory Configuration Description Parameter Integrated Memory Controller (iMC) When set to Enable, the system enforces Plan Of Record restrictions for DDR4 frequency and voltage programming. Enforce POR Options available: POR, Disable. Default setting is Disable. Configures the maximum memory frequency. If Enforce POR is disabled, user will be able to run at higher frequencies than the Memory Frequency memory support (limited by processor support).
Page 80
Description Parameter Enable/Disable Automatic restoring of NVDIMMs. Restore NVDIMMs Options available: Enable, Disable. Default setting is Enable. Controls if NVDIMMs are interleaved together or not. Interleave NVDIMMs Options available: Enable, Disable. Default setting is Enable. Enable/Disable Assert ADR on Reset. Assert ADR on Reset Options available: Enabled, Disabled.
Page 81
Description Parameter Leaky bucket time window based interface – Enable/Disable leaky bucket time window based interface. – Options available: Disabled, Enabled. Default setting is Disabled. Leaky bucket low bit – Configures leaky bucket low bit (1-63). – Press the <+> / <-> keys to increase or decrease the desired values.
5-3-5 IIO Configuration Description Parameter IIO Configuration Press [Enter] to configure advanced items. ® Intel VT for Directed I/O – Enable/Disable the Intel VT for Directed I/O (VT-d) support function by reporting the I/O device assignment to VMM through DMAR ACPI Tables.
5-3-6 Advanced Power Management Configuration Description Parameter Advanced Power Management Configuration Press [Enter] to configure advanced items. SpeedStep (Pstates) – Conventional Intel SpeedStep Technology switches both voltage and frequency in tandem between high and low levels in response to processor load. –...
Page 85
Description Parameter Press [Enter] to configure advanced items. Hardware P-States – When this item is disabled, the processor hardware chooses a P-state based on OS Request (Legacy P-States). – In Native mode, the processor hardware chooses a P-state based Hardware PM State Control on OS guidance.
5-3-7 PCH Configuration Description Parameter PCH Configuration Press [Enter] to configure advanced items. SATA Controller – Enable/Disable SATA controller. – Options available: Enable, Disable. Default setting is Enable. Configure SATA as – Configures on chip SATA type. – AHCI Mode: When set to AHCI, the SATA controller enables its AHCI functionality.
Page 87
Description Parameter Port 0/1/2/3/4/5/6/7 – Enable/Disable Port 0/1/2/3/4/5/6/7 device. – Options available: Enable, Disable. Default setting is Enable. Hot Plug (for Port 0/1/2/3/4/5/6/7) (Note 2) – Enable/Disable HDD Hot-Plug function. PCH SATA Configuration – Options available: Enable, Disable. Default setting is Enable. (continued) Spin Up Device (for Port 0/1/2/3/4/5/6/7) (Note 2)
5-3-8 Miscellaneous Configuration Description Parameter Miscellaneous Configuration Selects the active video type. Options available: Auto, Onboard Device, PCIE Device, Specific PCIE Active Video Device. Default setting is Auto. - 88 - BIOS Setup...
5-3-9 Server ME Configuration Parameter Description General ME Configuration Oper. Firmware Version Displays the operational firmware version. ME Firmware Status #1/#2 Displays ME Firmware status information. Current State Displays ME Firmware current status information. Error Code Displays ME Firmware status error code. Recovery Cause Displays ME Firmware recovery cause.
5-3-11 Power Policy Description Parameter Selects a Power Policy Quick Setting. Options available: Standard, Best Performance, Energy Efficient, Turbo Power Policy Quick Settings Lock. Default setting is Standard. Conventional Intel SpeedStep Technology switches both voltage and frequency in tandem between high and low levels in response to processor SpeedStep (Pstates) load.
Page 93
Description Parameter The Hyper Threading Technology allows a single processor to execute two or more separate threads concurrently. When hyper-threading is enabled, multi-threaded software applications can execute their threads, Hyper-Threading [ALL] thereby improving performance. Options available: Enabled, Disabled. Default setting is Enabled. Options available: Enabled, Disabled.
Server Management Menu Parameter Description Enable/Disable FRB-2 timer (POST timer). FRB-2 Timer Options available: Enabled, Disabled. Default setting is Disabled. FRB-2 Timer (Note1) Configures the FRB2 Timer timeout. The value is between 1 to 30 minutes. timeout Default setting is 6 minutes. Configures the FRB2 Timer policy.
Page 95
Parameter Description System Event Log Press [Enter] to configure advanced items. View FRU Press [Enter] to view the FRU information. Information BMC VLAN Press [Enter] to configure advanced items. Configuration BMC network Press [Enter] to configure advanced items. Configuration IPv6 BMC Network Press [Enter] to configure advanced items.
5-4-1 System Event Log Parameter Description Enabling / Disabling Options Change this item to enable or disable all features of System Event SEL Components Logging during boot. Options available: Enabled, Disabled. Default setting is Enabled. Erasing Settings Choose options for erasing SEL. Options available: No, Erase SEL Yes, On next reset,...
5-4-2 View FRU Information The FRU page is a simple display page for basic system ID information, as well as System product information. Items on this window are non-configurable. (Note) The model name will vary depends on the product you purchased - 97 - BIOS Setup...
5-4-3 BMC VLAN Configuration Description Parameter BMC VLAN Configuration Select to configure BMC VLAN ID. The valid range is from 0 to 4094. When BMC VLAN ID set to 0, BMC VLAN ID will be disabled. Select to configure BMC VLAN Priority. The valid range is from 0 to 7. BMC VLAN Priority When BMC VLAN ID is set to 0, BMC VLAN Priority will not be selected.
5-4-4 BMC Network Configuration Parameter Description BMC network configuration Lan Channel 1 Selects to configure LAN channel parameters statically or dynamically (DHCP). Do nothing option will not modify any BMC network parameters Configuration Address source during BIOS phase. Options available: Unspecified, Static, DynamicBmcDhcp. Default setting is DynamicBmcDhcp.
5-4-5 IPv6 BMC Network Configuration Parameter Description IPv6 BMC network configuration IPv6 BMC Lan Channel 1 Enable/Disable IPv6 BMC LAN channel function. When this item is disabled, the system will not modify any BMC network during BIOS IPv6 BMC Lan Option phase.
Security Menu The Security menu allows you to safeguard and protect the system from unauthorized use by setting up access passwords. There are two types of passwords that you can set: • Administrator Password Entering this password will allow the user to access and change all settings in the Setup Utility. •...
5-5-1 Secure Boot The Secure Boot submenu is applicable when your device is installed the Windows 8 (or above) operating ® system. Parameter Description System Mode Displays if the system is in User mode or Setup mode. Enable/ Disable the Secure Boot function. Secure Boot Options available: Enabled, Disabled.
Page 103
Parameter Description Press [Enter] to configure advanced items. Please note that this item is configurable when Secure Boot Mode is set to Custom. Factory Key Provision – Allows to provision factory default Secure Boot keys when system is in Setup Mode.
Page 104
Parameter Description Authorized TimeStamps (DBT) – Displays the current status of the Authorized TimeStamps Database. – Press [Enter] to configure a new DBT or load additional DBT from storage devices. Key Management – Options available: Update, Append. (continued) OsRecovery Signatures ...
Boot Menu The Boot menu allows you to set the drive priority during system boot-up. BIOS setup will display an error message if the legacy drive(s) specified is not bootable. Parameter Description Boot Configuration Number of seconds to wait for setup activation key. 65535 (0xFFFF) Setup Prompt Timeout means indefinite waiting.
Page 106
Parameter Description FIXED BOOT ORDER Priorities Press [Enter] to configure the boot order priority. By default, the server searches for boot devices in the following sequence: Hard drive. Boot Option #1 / #2 / #3 / #4 / #5 CD-COM/DVD drive. USB device.
Save & Exit Menu The Save & Exit menu displays the various options to quit from the BIOS setup. Highlight any of the exit options then press <Enter>. Parameter Description Save Options Saves changes made and closes the BIOS setup. Save Changes and Exit Options available: Yes, No.
Page 108
Parameter Description Loads the default settings for all BIOS setup parameters. Setup Defaults are quite demanding in terms of resources consumption. If you are using low-speed memory chips or other kinds of low-performance components Restore Defaults and you choose to load these settings, the system might not function properly.
BIOS POST Beep code (AMI standard) 5-8-1 PEI Beep Codes # of Beeps Description Memory not Installed. Memory was installed twice (InstallPeiMemory routine in PEI Core called twice) Recovery started DXEIPL was not found DXE Core Firmware Volume was not found Recovery failed S3 Resume failed Reset PPI is not available...