The charts in Figure 2 indicate technical inform-
ation regarding the installation of your gas log set.
Please make sure that all of the specifications
shown are applicable before installation is attempt-
ed.
The fireplace must include a working flue and venting
system with the minimum openings shown in the
Figure 2.
MINIMUM FIREBOX SIZE
LOG
FRONT
BACK
SIZE
WIDTH
WIDTH* DEPTH HEIGHT
/
"
24"
35
3
17"
4
FUEL PRESSURE
SPECIFICATIONS (W.C.)
NG 5.5"-10.5"
LP
11"-13"
* ± .2"
DESCRIPTION
24" Dual Burner
BURNER ORIFICE
LOG
NATURAL
SIZE
In.
Num.
24"
.144
#27
Figure 2 - Technical Information Charts
CONNECTING TO GAS SUPPLY
WARNING: A qualified service person must
connect log set to gas supply. Follow all
local codes.
Installation Items Needed
Before installing log set, make sure you have
the items listed below.
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve
• adjustable (crescent) wrench or pliers
• sediment trap
• tee joint
• pipe wrench
CAUTION: Use only new, black iron or
steel pipe. Internally-tinned copper tubing may
be used in certain areas. Check your local
codes. Use pipe of 1/2" diameter or greater to
allow proper gas volume to log set. If pipe is too
small, undue loss of volume will occur.
MINIMUM
FLUE SIZE
/
"
8" dia.
15
1
18"
2
Inlet
Manifold*
3.5"
10"
Btu\Hr Input
Btu\Hr Input
Natural Gas
Propane Gas
60,000
60,000
PROPANE/LP
In.
Num.
.089"
#43
INSTALLATION
Continued
CHECK GAS TYPE
Use only natural gas. If your gas supply is not nat-
ural gas, you must convert the appliance to propane
/LP. Follow the instructions on page 7.
If the fireplace does not have a gas supply shutoff
valve, one must be installed.
INSTALLING DAMPER CLAMP
Secure the damper stop clamp provided to the leading
edge of the damper as shown in Figure 3. If for any rea-
son this clamp doesn't work on your fireplace, another
suitable clamp or permanent stop must be installed, or
the damper blade must be cut or removed.
Masonry Fireplace
CONNECTING TO GAS SUPPLY
Continued
Installation must include an equipment shutoff valve with
"T" style handle, gas union and, for propane/LP gas only,
a plugged 1/8" NPT pressure tap. Locate NPT tap within
reach for test gauge hook up. NPT tap must be upstream
from log appliance (see Figure 4 on Page 6).
IMPORTANT: Install equipment shutoff valve in an ac-
cessible location. The equipment shutoff valve is for
turning on or shutting off the gas to the appliance.
Apply pipe joint sealant lightly to male NPT threads. This
will prevent excess sealant from going into pipe. Excess
sealant in pipe could result in a clogged burner injector.
WARNING: Use pipe joint sealant that is resistant
to liquid petroleum (LP) gas.
Damper
Clamp
Damper
Damper
Clamp
Damper
-
Manufactured Fireplace
Figure 3 - Attaching Damper Clamp
Damper