Dometic RM2451 Operating Instructions Manual page 13

Hide thumbs Also See for RM2451:
Table of Contents

Advertisement

MAINTENANCE & SERVICE
CLEANING THE BURNER
1. Turn off the refrigerator
2. Unplug the power cord from the 120 VAC out-
let. Disconnect the wires or shut off the 12 VDC
power supply to the refrigerator.
3. Turn off the manual shut off valve.
4. Remove cover from burner housing.
5. Clean the burner tube with a brush. Blow out the
burner with compressed air.
FIRE HAZARD. Never use a wire or pin to clear
obstructions from the burner jet as damage
will occur. Do not attempt to adjust the burner
jet. Failure to obey this warning could cause
a fire resulting in death or serious injury.
6. Verify that the burner jet slots are centered un-
der the flue tube.
7. Be sure to check the burner flame for proper ap-
pearance. The flame should be clear blue over
the slots of the burner.
Slots Centered
Under Flue Tube
8. Check the electrode for proper location and gap.
Adjustments may be made with needle nose pli-
ers if necessary.
Electrode
Burner Tube
9. Turn on the manual gas shut off valve.
10. Examine all fittings for leaks. Use a commercial
non-corrosive bubble solution.
11. Connect the 120 VAC power cord.
12. Reconnect/Turn on the 12 VDC power.
13. Check LP gas safety shutoff.
Clear Blue Color
Of Flame
1/8" to 3/16"
(3-5 mm)
REFRIGERATOR REMOVAL / DIS-
POSAL
To be performed by a qualified service technician
only.
See Installation Instructions for refrigerator removal /
replacement procedure, and for recycle information.