Download Print this page

Flowzone CYCLONE 2V Operation Manual page 11

4-gallon variable pressure lithium-ion backpack sprayer

Advertisement

7
Copyright © WESSOL, LLC
TROUBLESHOOTING
YOUR SPRAYER
PROBLEM
Battery is not charged.
Sprayer does not
turn on.
Loose wire.
Input and/or output hose(s)
Leaks from tank area.
have a loose connection with
the pump.
Loose / damaged / broken
seal(s)
Leaks from gun/nozzle
area.
Ball valve inside gun assembly
is defective
Not rinsing tank / pump / hose
Clogged pump / hose /
/ gun / nozzle(s) with cleaning
gun / wand / nozzle.
solution or water after use.
Random part breaks.
Wear and tear.
Pump runs constantly or
Pressure switch adjustment is
intermittently.
needed on the pump.
POSSIBLE REASON(S)
SOLUTION
Charge battery.
Contact FlowZone® Support at +1 (803)
339-2500 for service.
Remove screws and remove the
plastic covering to expose pump.
Loosen clamps on both hoses,
position hose closer to pump and
re-tighten hose clamp.
Inspect all seals and replace if
necessary.
Contact FlowZone® at +1 (803) 339-
2500 for warranty info.
Rinse sprayer throughly with warm,
soapy water after each use. Wipe
down pump input filter inside tank.
Contact FlowZone® at +1 (803) 339-
2500 for warranty coverage.
Contact FlowZone® Support at +1(803)
339-2500 for service.
Copyright © WESSOL, LLC

Advertisement