5.2.4 How to Clear the Error Buffer
The error code buffer is cleared in the following cases:
• By using the CLEAR command in the SAM menu
• By using the CLEAR command in the Factory mode:
• By using the following key sequence on the remote control transmitter: "062599" directly followed by the OK button.
• If the contents of the error buffer have not changed for 50 hours, the error buffer resets automatically.
Note: If you exit SAM by disconnecting the mains from the television set, the error buffer is not reset.
5.3 Set Option Code
Press the following key sequence on a standard RC transmitter: "062598" directly followed by MENU and "xxx", where "xxx" is a 3 digit decimal value
of the panel type: see column "Set Option Code" in below tab. After resetting the Display Code, restart the set immediately.
CTN_ALT
BOM#
50PUT8215/56
50PUT8215/67
50PUT8215/68
50PUT8215/70
50PUT8215/73
Panel Type
TPT500B5-U2T01.D S01J XY
TPV
TPT500B5-U2T01.D S01J XY
TPV
TPT500B5-U2T01.D S01J XY
TPV
TPT500B5-U2T01.D S01J XY
TPV
TPT500B5-U2T01.D S01J XY
TPV
Pane
CTN_ALT
l ID
BOM#
67
55PUT8215/98
67
65PUT8215/56
67
65PUT8215/67
67
65PUT8215/68
67
65PUT8215/70
Panel Type
TPT550J1-QUBF84.K S89P0C
XM TPV
TPT650J1-QUBF90.K 9WP0V
XM TPV
TPT650J1-QUBF90.K 9WP0V
XM TPV
TPT650J1-QUBF90.K 9WP0V
XM TPV
TPT650J1-QUBF90.K_9WP0A
M XM TPV
Panel ID
68
69
69
69
69