Service and Maintenance
Engineers Forms
Should settings be changed from default, please enter and record new setting in 'Field Setting' column. This will ease resetting in the
future should the system use change or the circuit board need to be replaced.
Commissioning/Field settings record sheet
Main remote controller screen
Main
Option
Setting DHW
Legionella prevention
Heating
Compensa-
Hi flow temp.
tion curve
set point
Lo flow temp.
set point
Adjust
Holiday
Initial settings
Zone1 heating room temp.
Zone2 heating room temp. *8
Zone1 heating flow temp.
Zone2 heating flow temp. *1
Zone1 heating compensation
curve
Zone2 heating compensation
curve *1
Holiday mode
Forced DHW operation
DHW
Heating
Energy monitor
Operation mode
DHW max. temp.
DHW ma. temp. drop
DHW max. operation time
DHW mode restriction
DHW recharge
Active
Hot water temp.
Frequency
Start time
Max. operation time
Duration of maximum temp.
Zone1 operation mode
Zone2 operation mode *1
Zone1 outdoor ambient temp.
Zone1 flow temp.
Zone2 outdoor ambient temp.
*1
Zone2 flow temp. *1
Zone1 outdoor ambient temp.
Zone1 flow temp.
Zone2 outdoor ambient temp.
*1
Zone2 flow temp.*1
Zone1 outdoor ambient temp.
Zone1 flow temp.
Zone2 outdoor ambient temp.
*1
Zone2 flow temp. *1
DHW
Heating
Zone1 heating room temp.
Zone2 heating room temp. *8
Zone1 heating flow temp.
Zone2 heating flow temp. *1
Language
°C/°F
Summer time
Temp. display
Time display
Room sensor settings for
Zone1
Room sensor settings for
Zone2 *1
Room RC zone select *1
Parameters
10°C to 30°C
10°C to 30°C
20°C to 60°C
20°C to 60°C
−9°C to +9°C
−9°C to +9°C
Active/Non active/Set time
On/Off
On/Off/Timer
On/Off/Timer
Consumed electrical energy/Deliv-
ered energy
Normal/Eco
40°C to 60°C
5°C to 30°C
30 to 120 min
30 to 120 min
Standard/Large
Yes/No
60°C to 70°C
1 to 30 days
00:00 to 23:00
1 to 5 hours
1 to 120 min
Heating room temp./ Heating flow
temp./ Heating compensation curve
Heating room temp./ Heating flow
temp./ Heating compensation curve
−30°C to +33°C
20°C to 60°C
−30°C to +33°C
20°C to 60°C
−28°C to +35°C
20°C to 60°C
−28°C to +35°C
20°C to 60°C
−29°C to +34°C
20°C to 60°C
−29°C to +34°C
20°C to 60°C
Active/Non active
Active/Non active
10°C to 30°C
10°C to 30°C
20°C to 60°C
20°C to 60°C
EN/FR/DE/SV/ES/IT/DA/NL/FI/NO/
PT/BG/PL/CZ/RU/TR/SL
°C/°F
On/Off
Room/DHW tank/Room&DHW tank /
Off
hh:mm/hh:mm AM/AM hh:mm
TH1/Main RC/Room RC1-8/"Time/
Zone"
TH1/Main RC/Room RC1-8/"Time/
Zone"
Zone1/Zone2
Default
Field
Notes
setting
setting
20°C
20°C
45°C
35°C
0°C
0°C
On
On
Eco
50°C
10°C
60 min
30 min
Standard
Yes
65°C
15 days
03:00
3 hours
30 min
Room temp.
Compensation
curve
−15°C
50°C
−15°C
40°C
35°C
25°C
35°C
25°C
Non active
Active
15°C
15°C
35°C
25°C
EN
°C
Off
Off
hh:mm
TH1
TH1
Zone1
(Continued to next page.)