Installation Instructions
WARNING
!
Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use infor-
mation can result in death, serious personal injury,
property damage, or damage to the equipment.
Keep this Manual for future reference.
WARNING
!
Need for Periodic Inspection/Maintenance: This product
must be tested periodically in compliance with local codes,
but at least once per year or more as service conditions
warrant. All products must be retested once maintenance
has been performed. Corrosive water conditions, inlet tem-
peratures over 200°F (93°C), and/or unauthorized adjustments
or repair could render the product ineffective for the service
intended. Regular checking and cleaning of the product's
internal components helps assure maximum life and proper
product function.
Installation
n
1. Flush all piping thoroughly before installing.
2. Remove knobs A, B, and C.
3. Remove the four-bracket screws (D) and panel screws (E)
then remove stainless steel box assembly.
Do not remove front panel from box.
There are six (6) bracket screws on the pressure
equalizing models.
4. For wall mounting, use rough-in drawing to locate mounting
holes on wall. Mount bracket to wall. Do not remove mixer
assembly from bracket.
Thermometer Calibration
1. If thermometer should need calibration, remove front knobs
A, B, and C and the front panel screws E.
440-1000
CAPACITY
"A"
6 gpm
5-7/8
1-1/2
n
"B"
"C"
"D"
"E"
2-7/16
2-3/8
4-3/4
SERIES 440 FOTOPANEL
5. Make final connections to hot and cold supplies and outlet
from vacuum breaker. Facing front of mixer, connect hot
water to left side (marked HOT) and cold water to right side
(marked COLD). Inlet connections must be piped correctly for
proper operation of Fotopanel.
WARNING
!
Do not exert excessive torque on the outlet pipe when connecting
it to the vacuum breaker which is supported by a plastic manifold.
6. Replace stainless steel box assembly and attach knobs
A, B, and C and the front panel screws E.
2. Calibration screw is located on back of thermometer case.
440-3000
CAPACITY
"A"
"B"
14 gpm
5-3/4
1-3/4
ROUGHING- IN DIMENSIONS
TOP EDGE OF CABINET
4-19/32"
3-5/8"
HOLE SIZE
(TO SUIT METHOD
OF FASTENING)
IS-P-129_025
"C"
"D"
"E"
2-11/16
2-7/16
6-3/4
MUST BE LEVEL
2-3/4"
4-19/32"
VERTICAL CENTER
LINE OF CABINET