Connecting A Normal Relay As Battery Disconnect Device - Whisper Power Lithium Plus User Manual

Power battery 12 v 210 ah / 12 v 340 ah / lifepo4 iron phosphate batteries
Table of Contents

Advertisement

WhisperPower Lithium Plus 12 V 210 Ah 340 Ah
19
Load/Charger
Bi-stable Relay
Figure 6. Connect a bi-stable relay as Battery Disconnect device

4.5.2. Connecting a normal relay as Battery Disconnect device

1. When using a normal relay, connect it to Con 2 (I/O Connection 7), Pin 4 (Rc) and Pin 5
(Rnc) as displayed in Figure 7.
Load/Charger
Normal relay
Figure 7. Connect a normal relay as Battery Disconnect device.