Download Print this page
Hide thumbs Also See for CLICKER 4:

Advertisement

Quick Links

C L I C K E R 4
I N V E R T E R S h i e l d
U S E R M A N U A L

Advertisement

loading
Need help?

Need help?

Do you have a question about the CLICKER 4 and is the answer not in the manual?

Questions and answers

Summary of Contents for Mikroe CLICKER 4

  • Page 1 C L I C K E R 4 I N V E R T E R S h i e l d U S E R M A N U A L...
  • Page 2 Thank you for choosing MIKROE! We present you the ultimate solution for embedded development. Elegant on the surface, yet extremely powerful on the inside, we have designed it to inspire outstanding achievements. And now, it’s all yours. Enjoy premium. Time-saving embedded tools...
  • Page 3: Table Of Contents

    Table of contents Introduction 1. Power Supply 2. MOSFET Power Stage 3. Integrated Driver 4. Encoder 5. CAN 6. Headers...
  • Page 4: Introduction

    Clicker 4 Inverter Shield is an extension for Clicker 4 series boards from MIKROE. It is the perfect way to expand the functionalities of your Clicker 4 board to provide highly efficient control and drive solutions for brushless DC (BLDC) motors.
  • Page 5: Power Supply

    5V/2A regulated power source. The 5V output is also connected to pin 36 (EXT) of HDR2 side header, and can be used to power the controller board. CLICKER 4 Inverter Shield U S E R M A N U A L...
  • Page 6: Mosfet Power Stage

    ON-resistance level MOSFET is achieved. The LM61 device (2), a precision, integrated-circuit temperature sensor is also in this section, providing a easy to read linear output to acquire board temperature. CLICKER 4 Inverter Shield U S E R M A N U A L...
  • Page 7: Integrated Driver

    (LD5), WH (LD6) LEDs (Blue) are used to indicate the state of High-side gate driver control inputs. FLT1 LED (Red) is a fault indicator, this LED turns on during a fault condition. CLICKER 4 Inverter Shield U S E R M A N U A L...
  • Page 8: Encoder

    MCU on the Clicker 4 board. The MAX14890E detects common RS-422/ HTL/TTL/DI faults. These faults include low differential input signals, open-wire, short-circuits, and inputs voltages that CLICKER 4 Inverter Shield U S E R M A N U A L...
  • Page 9: Can

    CANL and CANH are exposed over terminal block TB6, and TX/RX signals are connected to side header. The jumper labeled as J8 is used to enable the 120 Ohm termination resistor. CLICKER 4 Inverter Shield U S E R M A N U A L...
  • Page 10: Headers

    6. Headers All important signals are routed to two 1x20 pin headers, making them available for further connectivity. INTERRUPT DIGITAL ANALOG I/O1 I/02 INTERRUPT ANALOG DIGITAL CLICKER 4 Inverter Shield U S E R M A N U A L...
  • Page 11 D I S C L A I M E R All the products owned by MikroElektronika are protected by copyright law and international copyright treaty. Therefore, this manual is to be treated as any other copyright material. No part of this manual, including product and software described herein, must be reproduced, stored in a retrieval system, translated or transmitted in any form or by any means, without the prior written permission of MikroElektronika.
  • Page 12 If you are experiencing some problems with any of our products or just need additional information, please place your ticket at www.mikroe.com/support Time-saving embedded tools If you have any questions, comments or business proposals, do not hesitate to contact us at office@mikroe.com...

This manual is also suitable for:

5134