3.0 SYSTEM WIRING CONFIGURATIONS

The A 6500 Wall Plate can be configured to operate with either the A 6505, A 6510 or A 6515 or a combination of these.

3.1 STANDARD SERIAL, IR and RELAY SETUP

Shown below is the standard setup with the A 6500 Wall Plate connected to the A 6505 Serial Hub via a CAT5e/6 cable. 24V
DC power is connected to the A 6505 by a plugpack with a 2.1mm jack or through the euro block terminals. The
A 6505 in turn powers the A 6500 Wall Plate through the Cat5e/6 cable.
The A 6505 Serial Hub can then be connected to up to two RS232 or RS485 controlled devices. IR control of multiple devices
is available through the IR repeater output and a total of three relay outputs enable control of devices with a closing contact.
The relay contacts are rated at 2A maximum and a set of normally open and normally closed contacts are available for each
relay.
Redback® A 6500
3.2 TWELVE RELAY SETUP (NO SERIAL or IR)
The simple setup provides up to twelve output relays for switching, with no serial or IR outputs. The A 6500 Wall Plate is
connected to the A 6510 via a CAT5e/6 cable. 24V DC power is connected to the A 6505 by a plugpack with a 2.1mm jack
or through the euro block terminals. The A 6510 in turn powers the A 6500 Wall Plate through the Cat5e/6 cable. The relay
contacts are rated at a maximum of 1A with a set of normally open contacts only.
Redback® A 6500
8
Redback® Proudly Made In Australia
(Cat5/6 Cable 50m Maximum)
RS232/
RS485
Fig 3.1
(Cat5/6 Cable 50m Maximum)
12
11
10
Fig 3.2
Relay OUT
1
2
3
IR
RS232/
A 1052 IR REPEATER
RS485
Relay OUT
9
8
7
6
5
4
3
2
1
System Configurations
24V DC PLUGPACK
(MINIMUM 1A)
Redback® A 6505
RELAY CONTROLLED DEVICES
(CONTACTS MAX 2A)
24V DC PLUGPACK
(MINIMUM 1A)
Redback® A 6510
RELAY CONTROLLED DEVICES
(CONTACTS MAX 1A)

Advertisement