System Configurations
3.6 SERIAL and IR CONTROL with THREE LOW POWER and TWO HIGH CURRENT RELAYS
This configuration expands the standard setup to provide serial and IR control with 3 low power output relays and two high
current output relays.
The A 6500 Wall Plate is connected to the A 6505 Serial Hub via a CAT5e/6 cable. 24V DC power is connected to the A6505
by a plugpack with a 2.1mm jack or through the euro block terminals. The A 6505 in turn powers the A 6500 Wall Plate
through the Cat5e/6 cable and powers the A 6515 by running a cable from the 24DC In terminals of the A 6505 to the A
6515 24V In terminals.
The A 6505 Serial Hub can then be connected to up to two RS232 or RS485 controlled devices. IR control of multiple devices
is available through the IR repeater output and a total of five relay outputs enable control of devices with a closing contact.
The relay contacts on the A 6505 are rated at 2A maximum and a set of normally open and normally closed contacts are
available for each relay. The relay contacts on the A 6515 are rated at 16A maximum with a set of normally open and nor-
mally closed contacts for each relay.
Redback® A 6500
Redback® Programmable Control System
(Cat5/6 Cable 50m Maximum)
RS232/
RS485
Fig 3.6
Redback® A 6505
Relay OUT
1
2
3
IR
RS232/
A 1052 IR REPEATER
RS485
Redback® A 6515
Relay OUT
2
1
Redback® Proudly Made In Australia 11
24V DC PLUGPACK
(MINIMUM 1A)
RELAY CONTROLLED
DEVICES
RELAY CONTROLLED DEVICES
(CONTACTS MAX 16A)