TransLite TL-9542 Manual

1 sdi to 4 atsc encoder modulator

Advertisement

Quick Links

P a g e
| 1
PRODUCT MODEL NUMBER:
TL-9542 1 SDI TO 4
ATSC Encoder Modulator
ABOUT THIS
MANUAL
DISCLAIMER
No part of this document may be reproduced in any form without the written permission of the copyright
owner.
The contents of this document are subject to revision without notice due to continued progress in
methodology, design and manufacturing. TRANSLITE GLOBAL LLC shall have no liability for any error or
damage of any kind resulting from the use of this document.
COPY WARNING
This document includes some confidential information. Its usage is limited to the owners of the
product that it is relevant to. It cannot be copied, modified, or translated in another language
without prior written authorization from TRANSLITE GLOBAL LLC

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TL-9542 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TransLite TL-9542

  • Page 1 The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. TRANSLITE GLOBAL LLC shall have no liability for any error or damage of any kind resulting from the use of this document.
  • Page 2: Table Of Contents

    P a g e INDEX TABLE OF CONTENTS CHAPTER 1 INTRODUCTION ........................3 1.1 PRODUCT OVERVIEW ........................3 1.2 KEY FEATURES ..........................3 1.3 SPECIFICATIONS..........................4 1.4 PRINCIPLE CHART..........................6 1.5 APPEARANCE AND DESCRIPTION ...................... 6 CHAPTER 2 INSTALLATION GUIDE ......................
  • Page 3: Chapter 1 Introduction

    Blue-ray players, and antenna etc. Its output signals are to be received by TVs, STB etc., with corresponding standard. With its various inputs available, our TL-9542 series products are wildly used in public places such as metro, market hall, theatre, hotels, resorts, etc., for advertising, monitoring, training and educating in company, schools, campuses, hospital.
  • Page 4: Specifications

    P a g e ➢ Support low delay encoding mode (Optional) ➢ Support VBR/CBR rate control mode ➢ Support PSI/SI editing ➢ Support PCR accurate adjusting ➢ Support PID re-mapping and passthrough ➢ Digital ATSC RF out and ASI out; IP out ➢...
  • Page 5 P a g e Encoding Section – Audio MPEG1 Layer II ,MPEG2-AAC, MPEG4-AAC Encoding and Dolby Digital AC3 2.0( Optional) Sample rate 48KHz Bitrate 64/96/128/ 192/256/320kbps Modular Section ATSC Standard ATSC A/53 Constellation 8 VSB RF output level -26~-10dbm (81~97dbµV), 0.1db step ≥42dB RF frequency 30~960MHz, 1KHz step...
  • Page 6: Principle Chart

    P a g e PRINCIPLE CHART APPEARANCE AND DESCRIPTION Front Panel Illustration 6 7 8 9...
  • Page 7 P a g e LCD Screen NMS Port Data Port Power and Alarm Indicators TS Lock Indicators Up and Down, Left and Right Buttons Enter Mode: For Confirm Menu Button: For Back Step Lock Button: Press to Lock Set Rear Panel Illustration SDI Input interface RF Input interface...
  • Page 8: Chapter 2 Installation Guide

    ACQUISITION CHECK When users open the package of the device, it is necessary to check items according to packing list. Normally it should include the following items: ➢ TL-9542 Encoder Modulator ➢ User’s Manual ➢ ASI Cable ➢...
  • Page 9: Device's Installation Flow Chart

    P a g e DEVICE’S INSTALLATION FLOW CHART ENVIRONMENT REQUIREMENT Item Requirement When user installs machine frame array in one machine hall, the distance Machine Hall between 2 rows of machine frames should be 1.2~1.5m and the distance Space against wall should be no less than 0.8m. Electric Isolation, Dust Free Volume resistivity of ground anti-static material: 1X107~1X1010...
  • Page 10: Grounding Requirement

    P a g e | 10 GROUNDING REQUIREMENT ➢ All function modules’ good grounding is the basis of reliability and stability of devices. Also, they are the most important guarantee of lightning arresting and interference rejection. Therefore, the system must follow this rule. ➢...
  • Page 11: Wire's Connection

    When the device adopts united way, the grounding resistance should be smaller than 1Ω. Caution: Before connecting power cord to TL-9542 Encoder Modulator, user should set the power switch to “OFF”. SIGNAL CABLE CONNECTION The signal connections include the connection of input signal cable and the connection of output signal cable.
  • Page 12: Asi Output Cable Illustration

    NETWORK CABLE ILLUSTRATION CHAPTER 3 OPERATION TL-9542 Encoder Modulator’s front panel is user operating interface. Before operating, user can decide whether directly use the default setting or customize the input and output parameters setting. The detail operations go as follows:...
  • Page 13: Lcd Menu Structure

    P a g e | 13 LOCK: To Lock the screen / cancel the lock state. After pressing lock key, the system will question the users to save present setting or not. If not, the LCD will display the current configuration state.
  • Page 14 P a g e | 14 3.1 Output A 3.1.1 RF frequency 3.1.2 RF level 3 Modulator 3.1.3 RF on 3.1.4 ASI output 3.2 Output B Same content as “Output A” 3.3 Output B 3.4 Output B TSID 4.1 Output A ONID ASI Output 4.2 Output B...
  • Page 15: General Settings For Main Menu

    P a g e | 15 Initial Status After powering on the device,it will take a few seconds to initialize the system It shows as below: IP: 192.168.0.136 Start OK… Startup… X.XXMbps X.XXMbps ➢ IP: Indicating the IP address of this device ➢...
  • Page 16 Audio Video Format Video Format Program Info MPEG-2 Low Delay Video Bitrate Low Delay Normal Video Bit Rate 12.000 Mbps Note: TL-9542 support CC function only for SDI encoding module Under submenu 2.2, user can set the audio corresponding parameters.
  • Page 17 ➢ Audio format When entering “Audio format” submenu, user can select the audio format for this encoding module, TL-9542 support MPEG-1 Layer II, MPEG-2 AAC, MPEG-4 AAC and AC3. The LCD window would show as below: Audio format MPEG-1 Layer II ➢...
  • Page 18 3.2 Output B 3.4 Output D As the TL-9542 (DVB-C Modulating) is with 4 carrier outputs, “3.1”-“3.4” represent the “Carrier A”, “Carrier B”, “Carrier B”, and “Carrier D” respectively. User can enter “3.1”/“3.2”/“3.4”/“3.4” to set the corresponding modulating parameters. Submenus (taking “3.1” as an example) are as...
  • Page 19 P a g e | 19 3.1 Output A 3.1.1 RF On 3.1.3 Constellation 3.1.2 Standard 3.1.4 Symbol Rate 3.1.5 RF Frequency 3.1.7 ASI output 3.1.6 RF Level ➢ RF On This interface is to decide whether to enable the RF (carrier A) output or not. OFF: to disable programs to output through carrier A.
  • Page 20 P a g e | 20 ➢ RF level The RF attenuation range is from -30~-10dbm (81~97dbµV) with 0.1db step. After entering this setting submenu, user can shift UP/DOWN/LEFT/RIGHT key to set the output level and press ENTER to confirm. RF Level -10.0 dbm ➢...
  • Page 21 P a g e | 21 5) Network Network contains “5.1 NMS” and “5.2 IP Stream”. 5.1 NMS 5.2 IP Stream “5.1 NMS” is for setting the network parameters for the connection between the device and PC. 5.1.1 NMS IP 5.1.3 Gateway 5.1.2 Subnet Mask 5.1.4 MAC Address...
  • Page 22: Web Nms Operation

    User not only can use front buttons for setting configuration, but also can control and set the configuration in computer by connecting the device to web NMS Port. User should ensure that the computer’s IP address is different from the TL-9542’s IP address; otherwise, it would cause IP conflict.
  • Page 23: Operation

    P a g e | 23 Use web browser to connect the device with PC by inputting the Encoder & Modulator’s IP address in the browser’s address bar and press Enter. It will display the Login interface as Figure-1. Input the Username and Password (Both the default Username and Password are “admin”.) and then click “LOGIN”...
  • Page 24 P a g e | 24 System information It displays the signal source interface as User can click any item per you set in “Input here to enter the 1/2” interface and corresponding interface displays real-time to check information or encoding bit rate of set the parameters.
  • Page 25 P a g e | 25 General Settings for the input programs: User can edit any item listed as needed. Video Status: Green light indicates the corresponding source cables are properly connected. Encoding Status—Green light indicates the encoding process is running normally, which otherwise turn to red.
  • Page 26 P a g e | 26 …..……………………………………..NOTE ……..……..………………………………. The different combination of Video Format, Video Bit-rate, Low delay Mode and the Resolution of signal source will have an impact on the latency. Please refer to the Chapter 6 attached for detailed information. ……………………………………………………………………………………………………..……...
  • Page 27 P a g e | 27 The letters A to D represent the 4 carrier outputs. E represent the ASI output. User can configure different program group for each carrier output. If this item is selected, all the input programs will pass through without any elimination.
  • Page 28 P a g e | 28 Click “Add” to add more boxes for filling the Input & Output PIDs, then click “Apply” to confirm. VCT (Virtual Channel Table) Setting Click “VIT” from the menu to trigger the screen as Figure-5. Then click “Add” from this screen to add the program descriptor in VCT.
  • Page 29 P a g e | 29 : Click “Add” to add boxes where to configure parameters in its respective fields. After setting all the data, users need to click “Save” to save the setting. IP Output Click “IP Output” from the left menu, it will display the screen as Figure-7 where to configure the 4 IP SPTS output and 1IP MPTS output.
  • Page 30 P a g e | 30 To choose ASI output programs. Figure-8 Save/Restore Clicking “Save/Restore” from the menu, it will display the screen as Figure-9 where can save the configuration permanently to the device. Click “Save Configuration”, for store the data permanently to the device.
  • Page 31 P a g e | 31 Click “Reboot” from the menu, the screen will display as Figure-10. Here when clicking “Reboot” box, it will restart the device automatically. Figure-10 Update the Device Click “Firmware” from the menu it will display the screen as Figure-11. Here user can update the device by using the update file.
  • Page 32 P a g e | 32 Network When user clicks “Network”, it will display the screen as Figure-12. It displays the network information of the device. Here user can change the device network configuration as needed. Figure-12 Change Password When user clicks “Password”, it will display the password screen as Figure-13. Here user can change the Username and Password for login to the device.
  • Page 33 P a g e | 33 ➢ Keyboard and LCD Lock: If it is marked with “√”,the LCD and keyboard will be locked to avoid unexpected modification or view of the device information and configurations. User can’t operate the keyboard & LCD while only the device IP address can be noted in the LCD window IP Address 192.168.000.136...
  • Page 34: Low Delay Settings

    CHAPTER 5 LOW DELAY SETTINGS TL-9542 can achieve a signal low delay from encoding to STB decoding side. User can enable the low delay function in the web-server NMS interface as shown below: Click ‘Input 1’ or ‘Input 2’ to sent a low delay mode for each program:...
  • Page 35: Chapter 6 Troubleshooting

    CHAPTER 6 TROUBLESHOOTING All TRANSLITE products have passed the testing and inspection before ship out factory. The testing and inspection scheme already covers all the Optical, Electronic and Mechanical criteria which have been published by TRANSLITE. To prevent potential hazard, please strictly follow the operation conditions.
  • Page 36: Chapter 7 Packing List

    P a g e | 36 CHAPTER 7 PACKING LIST TL-9542 Encoder Modulator User's Manual ASI Cables Power Cord...

Table of Contents