6. If the FTS reads properly at the Reactor but not at
the end of the hose, check cable connections.
Verify that connections are tight.
NOTE: To assist in taking readings, order RTD Test
Kit 18E258. The kit includes two cables: one cable
with a compatible female connector and another
cable with a male connector. Both cables have
stripped wire at the other end for easy test probe
access. See the RTD Test Kit Wire Reference table.
3A8501A
RTD Test Kit Wire Reference
Pins Wire Color
1
Brown
2
Bare
3
Blue
4
Black
5
White
RTD Resistance vs. Temperature
RTD or FTS
Resistance Ohms
843
882
922
961
1000
1039
1078
1117
1155
1194
1232
1271
1309
1347
1385
Repair
RTD or FTS
Temperature °C (°F)
-40 (-40)
-30 (-22)
-20 (-4)
-10 (14)
0 (32)
10 (50)
20 (68)
30 (86)
40 (104)
50 (122)
60 (140)
70 (158)
80 (176)
90 (194)
100 (212)