SPECIFICATION

SUPPLY:
12VDC @ 100mA for
INDICATION:
AUDIBLE:
CONTROL:
OPTIONS:
DIMENSIONS:
MOUNTING:
TEMPERATURE:
1
2
ZONE 2
GJD EMERALD MK3
3000
230Vac 50Hz via ELCB/MCB. - unit fused at 13A
GJD Opal XL (6mA) or Elite Detectors (10mA)
Optional external 12VDC piezo sounder upto 50mA
Six 24 hour detector indicators which pulse during detection and
are steady after detection for the duration of the light on timer setting.
Internal warning tone which sounds on detection day and night,
and is button selectable. It has a steady tone for zone one and a
pulsed tone for zone two.
Controls upto 12 x GJD detectors. Switches two independent
areas of lighting with manual override when required.
Ability to link both lighting areas together.
Ability to have a timed auxiliary output.
Ability to activate lighting when linked to an intruder alarm panel.
146(W) x 86(H) x 56(D) mm Weight 507gm
Indoor use only.
Mount in a clean dry location on a secure flat surface
-10 TO + 55 Centigrade
Self contained - Class 2 independently mounted control.
GJD E
MERALD
3
T
HE
SECURITY LIGHTING CONTROLLER WHICH
ENABLES EXTERNAL AREAS TO BE
ACCURATELY MONITORED
WATTS OF LIGHTING AT NIGHT FOR A PRE
. T
HE CONTROLLER INCORPORATES AN
.
- 1 -
MK3 L
IGHTING
I
NSTALLATION
P
ART
GJD E
MERALD IS A DUAL AREA
C
ONTROLLER
M
ANUAL
N
: GJD010
O
.
-
SET PERIOD

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EMERALD MK3 and is the answer not in the manual?

Questions and answers

Brenda Heaton
May 23, 2025

Set alarm red light stays on see picture no one outside light will not go off!

User image 6830e90b6f546
1 comments:
Mr. Anderson
May 25, 2025

The red light on the GJD MK3 alarm stays on because the audible warning tone is selected. The outside light does not turn off because the detector is still receiving activation signals, keeping the light on for the length of the timer setting after the last detection.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for GJD EMERALD MK3

  • Page 1 It has a steady tone for zone one and a pulsed tone for zone two. CONTROL: Controls upto 12 x GJD detectors. Switches two independent areas of lighting with manual override when required. OPTIONS: Ability to link both lighting areas together.
  • Page 2 PERATING NSTRUCTIONS When a detector is activated day or night the relevant detector indicator flickers and will remain on for the length of the timer setting. During darkness the lighting will be switched on automatically while the detector is receiving activation signals, and will automatically turn off after the preset timer period.
  • Page 3 DJUSTMENT TO FACTORY SETTINGS When connecting the unit to the electrical supply or when the supply is interrupted, the indicators will flash for one minute whilst the system settles. Pressing any button during this time will start normal operation. Internal adjustments panel The factory settings are shown.
  • Page 4 (3) Activate zone lighting for alarm period when linked to an intruder alarm panel. All diodes: IN4148, IN4002 etc Caution if this equipment is intended for applications not specified please contact GJD prior to installation. GJD Reserve the right to alter the specification without notice.

This manual is also suitable for:

Gjd010

Table of Contents